Setup guide

Commercial System Notes
If the Aux Relay function is set for alarm silenced by User Code + # + 67, this
command may only be entered in the console emulation mode.
Do not use the common lobby logic function.
If fields 2*22 (Display Fire Alarms of other Partitions), 2*23 (Display Burg &
Panic of other Partitions), or 2*24 (Display Troubles of other Partitions) are
enabled, the zones that created the conditions cannot be viewed. You must go to
that zone's home partition to view.
If field 1*11 (Zone Bypass After Disarm) is enabled, you must use the
TouchCenter’s Console Emulation Mode and the commandsCode” + “64”
(unbypass all) or “Code” + “6” + “Zone Number” (unbypass zone) to remove zone
bypasses.
The First to Alarm Display Lock feature (field 1*10) is not supported by the
TouchCenter.
RF Low Battery messages are not supported by the TouchCenter except in the
Show Zones screen where a Battery Icon will be displayed for the zone with the
low battery.
On multi-partition systems when the user has access to multiple partitions and
arms the system, the TouchCenter will always ask the arm multiple partitions
question regardless of the “Arm Multi-Partitions” setting.
Residential System Notes
If the Clean Me option is set, when the maintenance signal is received you will
get a “Fire Maintenance” message and the Display Faults button will be shown.
However, if you display the faults, zone 1 will not be shown as a faulted zone.
If RF Jam Reports are selected and RF Jam is detected, the User Authorization
screen will display “Trouble ZN100 RF Receiver”. If you enter the console
emulation mode, the display will show “Check 90 RF Receiver Jam”.
Do not use the Custom Word reminder feature.
User Related Notes
Users added to the system using the TouchCenter graphic user screen must be
deleted from the TouchCenter using the graphic screen as well. Deleting users
from the panel by any other means (alpha keypad, console emulation mode, or
Compass downloader) will not automatically delete them from the
TouchCenter.
If the panel has exit tones enabled and you arm the system in the Away mode,
the TouchCenter will beep continuously throughout the exit period.
Use the console emulation mode for the following functions:
- Programming more than 10 system users.
- Programming the Pager report option for users of residential control panels (e.g.,
VISTA-15P and VISTA-20P).
- Special Function Key operations (such as macros or single-button paging).
- End-User Scheduling.
- To check for an “Alarm Cancelled” message if this feature has been enabled in
the system.