Setup guide
TouchCenter Installation and Setup Guide
2–4
2. Connect ground to the TouchCenter using step a or b below.
a. If powering the keypad from the control panel, connect the
AUX – terminal of the control panel to the – terminal block
position (GND terminal of the TouchCenter (black wire)).
b. If powering the keypad from a supplementary power supply,
connect the AUX – terminal of the control panel to the (–)
terminal of the supplementary power supply (black wire).
Then, connect the (–) terminal of the supplementary power
supply to the – terminal block position (GND terminal of the
TouchCenter (black wire)).
3. Connect Data Out terminal of the control panel to the Y terminal
block position (Data In terminal of the TouchCenter (yellow
wire)).
4. Connect the Data In terminal of the control panel to the G
terminal block position (Data Out terminal of the TouchCenter
(green wire)).
5. Mount the TouchCenter onto the mounting plate as shown in
Figure 3.
6. If required, locate the locking tab over the top mounting hole and
secure using (1) #2 x ¼" Phillips pan head screw (supplied).
WALL
MOUNTING
PLATE
TOUCHCENTER
TYPICAL
4 PLACES
6272-008-V0
IF REQUIRED, LOCATE LOCKING
TAB OVER TOP MOUNTING HOLE
AND SECURE WITH SCREW.
SCREW
LOCKING
TA B
NOTE
Figure 3. Mounting the TouchCenter