User`s manual

63
Partition-Specific Field
Descriptions
(continued)
2nd Page Fields
1*43 Enable Permanent Display Backlighting
Enter 1 if it is desired that backlighting for the console display remain on at
all times. Enter 0 if the display should remain unlit unless a key is pressed.
The backlighting then turns off again after a period of keypad inactivity.
Note that when a key is pressed, display backlighting turns on for all
consoles in that partition.
1*45 Enable Console Annun. During Exit Delay
Enter 1 if beeps from the consoles during exit delay is desired. Enter 0
for no console sound during exit delay.
1*47 Enable Chime Annun. On External Alarm Sounder
Enter 1 for chime annunciation using the external alarm sounder. If not
desired, enter 0.
1*52 Cancel Report Restriction
Enter 1 if no report restriction is desired. Enter 0 if cancel reports are to be
sent within Bell Timeout period only.
1*76 Access Control Relay
The system can be programmed to provide user activated access control.
If enabled, the assigned relay will pulse for 2 seconds when the user
enters his code and presses "0". Enter the relay number (00-16) for the
relay that will be used for access control. Enter 00 if not used in this
partition.
3rd Page Fields
2*05 Auto-Arm Delay
Enter the time between the end of the arming window and the start of auto
arm warning time in values of 01-14 times 4 minutes. Enter 00 if no delay
is desired. Enter 15 if auto arming is not desired.
2*06 Auto-Arm Warning Period
Enter the time 01-15 in one minute increments during which the user is
warned (ex. turn lights on/off, bell sounds, etc.) to exit the premises prior
to auto arming of the system.
2*07 Auto-Disarm Delay
Enter the time between the end of the disarming window and the start of
auto disarming of the system in values of 01-14 times 4 minutes. Enter
00 if no delay is desired. Enter 15 if auto disarming is not desired.
2*08 Enable Force Arm For Auto-Arm
Enter 1 if the system should automatically bypass any faulted zone when it
attempts to auto arm. Otherwise enter 0.
2*09 Enable Open/Close Reports By Exception
Enter 1 if it is desired that open/close reports be sent only if the
open/close occurs outside the arm and disarm windows. Open reports
will also be suppressed during the closing window in order to prevent false
alarms if the user arms the system, then reenters the premises to retrieve a
forgotten item. Note that openings and closings are still recorded in the
event log though. Enter 0 if exception reporting is not desired. Note: This
field must be set to 1 if late/early to open and late/early to close reports
are to be sent.
2*10 Restrict Disarming Only During Arm/Disarm Windows
Enter 1 if disarming of the system should be allowed only during the
arming/disarming windows, or if the system is in alarm (if 2*11 is set to "1").
Note that this applies only to operator level users. Installer, Master and
manager level users can disarm the system at any time. Enter 0 if disarming
can occur at any time.
2*18 Enable Goto For This Partition
Enter 1 if this partition is to be accessed by a GOTO command. Otherwise
enter 0.
2*20 Enable J7 Triggers By Partition
0=disable for displayed partition; 1=enable for displayed partition