User guide

8
Specifications
OTDR
Emitter Type Laser
Safety Class
Class I FDA 21 CFR 1040.10 and 1040.11,
IEC 60825-1: 2007-03
Center Wavelengths 1310/1550 nm
Dynamic Range (SNR = 1) 38/36 dB (1310/1550 nm)
Event Dead Zone
1
0.9 m
Attenuation Dead Zone
2
4.5 m
Pulse Widths 5, 10, 30, 100, 300 ns, 1, 3, 10, 20 ms
Range Settings 250 m to 256 km
Sampling Points max. 64,000 points
Min Data Point Spacing 0.125 m
Group Index of Refraction (GIR) 1.4000 to 1.6000
Distance Uncertainty (m)
3
± (1 + 0.0005% x distance + data point spacing)
Linearity ± 0.05 dB/dB (typical)
Trace File Format Bellcore GR-196 Version 1.1
Trace File Storage Media
Internal flash memory
USB flash drive
Downloadable from OTDR directly to PC
Trace File Storage Capacity Internal 1000 fibers
Data Transfer to PC USB
OTDR Modes Full Auto, Real Time, Expert
Tool Free adapters Modular cleanable SC/ST/FC/LC
1 Typical distance between the two points 1.5 dB down each side of a reflective
spike caused by a -45 dB event using 5 ns pulse width.
2 Typical distance from event location to point where trace is within 0.5 dB of
backscatter caused by a -45 dB event using 5 ns pulse width.
3 Does not include GIR uncertainty.
VISUAL FAULT LOCATOR
Emitter Type Laser
Safety Class
Class II FDA 21 CFR 1040.10 and 1040.11,
IEC 60825-1: 2007-03
Wavelength 650 nm
Output Power (nominal) 0.8 mW
M700 Compact Single-mode OTDR
POWER METER
Calibrated Wavelengths
850, 980, 1310, 1490, 1550, 1625 nm (displays
up to 3 simultaneously)
Detector Type Filtered InGaAs detector
Measurement Range (dBm) +26 to -50 dBm
Accuracy
4
±0.25
Measurement Units dB, dBm, mW
Wavelength ID
5
Yes
Set Reference Yes
Data Storage Yes
Tone Detection 270 Hz, 330 Hz, 1 kHz, 2 kHz
GENERAL
Size 27.4 x 19.3 x 7.1 cm (10.8 x 7.6 x 2.8 in)
Weight 2.3 kg ( 5 lb)
Operating Temperature -10 to +50°C, 0 to 90% RH (non-condensing)
Storage Temperature -20 to +60°C, 0 to 90% RH (non-condensing)
Power Rechargeable Li-Ion or AC power adapter
Battery Life
6
> 8 hours continuous OTDR testing
Recharge Time
7
4 hours
Display 6.5 in (16.51 cm), color, transflective
4 Accuracy measured at 25ºC and -10 dBm per N.I.S.T. standards.
5 Automatic wavelength identification and switching when used with Noyes Wave
ID Series Light Sources.
6 Typical, depending on display brightness.
7 Typical, from fully discharged to fully charged state, unit may be operating.
All specifications are subject to change.
All specifications valid at 25°C unless otherwise specified.
External battery charger available.
OTDR Fiber Accessories
MODEL NUMBER DESCRIPTION
FR1-SM-1KM-SC-FC Fiber Ring SM SC/FC 1000m
FR1-SM-1KM-SC-LC Fiber Ring SM SC/LC 1000m
FR1-SM-1KM-ASC-SC Fiber Ring SM SC-APC/SC-UPC 1000m
8500-20-0900 Wet Cleaning Kit for SC/FC/ST/LC Connectors