User guide

71
Notes:
1 250 µm coated fiber parameters are specified with OFI plunger in the “250/900/RIB” position.
2mm/ 3mm jacketed fiber parameters are specified with OFI plunger in the “2 mm/ 3 mm” position.
2 Unless noted otherwise, all specifications are typical. Actual results can vary by several dB depending on fiber type, coating mate-
rial, jacket color, jacket hardness, and other factors.
All specifications stated above are as measured at 25°C.
3 [CW] is a light signal that is not modulated.
[Traffic] is a light signal modulated by a random data sequence.
[Tone] is a light signal modulated into a nominal 50% duty cycle square wave.
Specifications
Detectable signal range
Fiber Type Parameter Wavelength, Signal OFI 200D OFI 400
250 µm coated fiber
(SMF-28 with 250 µm CPC6 coating)
Minimum detect level
(average power,
typical)
1310 nm, CW or Traffic
1310 nm, Tone
1550 nm, CW or Traffic
1550 nm, Tone
-40 dBm
-43 dBm
-45 dBm
-50 dBm
-45 dBm
-45 dBm
-50 dBm
-50 dBm
Insertion loss
(typical)
1310 nm
1550 nm
0.6 dB
2.5 dB
0.6 dB
2.5 dB
3 mm jacketed fiber
(SMF-28 with 250 µm CPC6 coating
and 3 mm, yellow jacket)
Minimum detect level
(average power,
typical)
1310 nm, CW or Traffic
1310 nm, Tone
1550 nm, CW or Traffic
1550 nm, Tone
-30 dBm
-32 dBm
-33 dBm
-37 dBm
-30 dBm
-30 dBm
-33 dBm
-33 dBm
Insertion loss
(typical)
1310 nm
1550 nm
0.8 dB
2.5 dB
1.0 dB
2.8 dB
Optical Specifications
Model OFI 200D OFI 400
Detector type InGaAs
Wavelength range 800 - 1700 nm
Calibrated size of fiber and wavelength N/A 250 µm (SMF-28) @1550 nm
Fiber stress <100 kPSI max
Fiber size 250 µm, 900 µm, 2 mm or 3 mm jacketed & ribbon fiber
Tone detection 2000 ±100Hz 270, 330, 1000, or 2000 Hz (±5%)
Core power measurement range N/A +13 dBm to – 50 dBm
SMF28/28E 250um @ 1550nm
Measurement units N/A dBm, dB
General Specifications
Display Type N/A Multi 7 segment LCD; 3 LEDs;
1 piezo buzzer
Power 1 x 9V Alkaline 2 x 1.5V Alkaline
Battery life >10,000 operations typical >10,000 operations typical
Operation temperature 0° to 50°C 90% RH (Non-condensing)
Storage temperature -30 to +60°C 90% RH (Non-condensing)
Dimensions (H x W x D) 8.5 x 1.5 x 1.1 in. (22 x 3.8 x 2.8 cm)
Weight 7.5 oz. (210 g) 6 oz (168 g)
OFI Optical Fiber Identifiers
Applications
Live fiber identification - used during
installation, maintenance, rerouting, or
restoration to positively identify fibers
prior to cutting and splicing
Tone detection
The OFI 400 models may also be used
for measuring core power or relative
power
Ordering Information
Model Includes
OFI 200D User's guide and carry case
OFI 400 User's guide and carry case