User guide

69
Features
Rugged, handheld, lightweight
In-service detection of upstream
(1310 nm) activity on FTTx networks
Determines which unparked splitter
pigtails are connected to ONTs
Does not require travel to customer
(ONT) site
Does not require disconnect of splitter
pigtails
Visual and audible indicators
Battery operated
Low battery indication
Applications
FACILITY RECOVERY: Harvest unparked splitter legs and F2 fibers not connected to sub-
scribers.
TROUBLE-S HOOTING: Real-time confirmation of OLT to ONT connectivity at the FDH.
Ordering Information
MODEL INCLUDES
OFI-FTTx
OFI-FTTx, user's guide, and carry
case
Specifications
MODEL OFI-FTTX
Network Types FTTx BPON, GPON, EPON, 1:4 splitter ratio
Network Locations Between splitter and customer ONT
Fiber Type 2mm jacketed SMF-28e ®, 15mm bend radius AFL Bend Insensitive, and equivalents
Induced Loss (Typ) < 1 dB @ 1550 nm
Test Time (Typ) 1 sec
Operating Range* Loss from ONT to FDH: 0 to 7 dB (BPON), 0 to 9 dB (GPON, EPON)
User interface Audio indicator and four red LEDs
Power 2 x AA batteries
Battery Life 800 tests typical
Operating Temperature -10 to 40°C
Storage Temperature -20 to 50°C
Dimensions (H x W x D) 22 x 3.8 x 3.2 cm (8.5 x 1.5 x 1.25 in)
Weight 0.23 kg (0.5 lbs)
* Maximum values are typical and depend on fiber type and jacket material.
OFI-FTTx Active ONT Detector
The OFI-FTTx is a rugged, handheld optical fiber identifier designed to identify the
presence or absence of an active Optical Network Terminal (ONT) on FTTx F2 fibers at the
Fiber Distribution Hub (FDH). During a test the F2 fiber does not have to be removed from
service. Thus the OFI-FTTx can verify whether a splitter pigtail at the FDH is connected
to an active circuit before it is disconnected for fault location or re-use. The OFI-FTTx
can help verify FTTx network records and recover splitter pigtails and F2 fibers that are
connected at the FDH but, in fact, are available for new customers.
When applied to a splitter pigtail at the FDH, the OFI FTTx will report either that the ONT is
‘Active’ or ‘Not Detected’. Time to complete each test is typically one second.
The OFI-FTTx is compatible with 2mm jumper cable containing standard single-mode
fiber, such as SMF-28e ®, or bend insensitive fiber (BIF) with a 15mm bend radius
specification, such as AFL Bend Insensitive.
The OFI-FTTx is powered by two standard AA alkaline batteries, provides a low battery
indication, and can typically be operated 800 times before battery replacement is
necessary.
Patent Pending