User guide

62
Features
Multimode and Single-mode testing
Loss measurements at 850 and 1300nm
Includes 50 and 62.5 µm mandrels
Field portable, battery operated
Certify 50 or 62.5 µm multimode fiber
links for any 850 or 1300nm application,
including Gigabit Ethernet (GBE)
N.I.S.T. traceable
MLP1 Fiber Optic Loss Test Kits
The MLP1 test kits are inexpensive solutions for testing multimode and single-mode
systems. By joining the OPM 1 optical power meter and the OLS1 optical light source, the
MLP1 is a great kit for beginners or network owners. Two versions of the MLP1 test kit
are available for testing Premises networks, LAN, and Gigabit Ethernet. The MLP1-1S test
kit includes the OPM1-2C power meter and OLS1-1C light source. The MLP1-2 test kit
combines the OPM1-2C optical power meter and OLS1-2C optical light source
Specifications
Model MLP1-1S MLP1-2
Optical Light Source OLS1-1C OLS1-2C
Output ports 2 2
Output wavelength 660 nm - red 850 + 35/-40nm 850 + 35/-40 nm 1300 + 50/-10 nm
Spectral width (typ) (FWHM) 30 nm 40 nm 40 nm 120 nm
Output power
-10 dBm
*
>-20 dBm -20 dBm >-20 dBm
Stability (@25°C, 5 min. warm-up) 0.1 dB over 8 hours 0.1 dB over 8 hours
Fiber size
1000 µm, 62.5 µm
**
62.5 µm
**
Emitter type LED, Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03
Power Typical 60 hours with 9V battery, optional AC adapter
Connector ST
Size (H x W x D) 14.0 x 8.1 x 3.8 cm (5.5 x 3.2 x 1.5 in)
Weight 0.65 lb (.29 kg)
*
-10 dBm output is into 1000 micron fiber.
* * May be used to test 50 or 62.5µm fiber with supplied mandrels.
Optical Power Meter OPM1-2C
Calibration wavelength 850, 1300, 1310, 1550 nm
Detector type Germanium (Ge)
Dynamic range +6 to -60 dBm
Accuracy (@ 25°C & -10.0 dBm) ±0.25 dB
Measurement units dBm
Power Typical 60 hours with 9V battery
Adapter caps order separately (ST, SC, FC, and others available)
Size (H x W x D) 14.0 x 8.1 x 3.8 cm (5.5 x 3.2 x 1.5 in)
Weight 0.58 lb (0.26 kg)
General Kit Specifications MLP1-1S MLP1-2
Dynamic range:
Multimode ( 62.5/125 µm)
Single-mode ( 9/125 µm)
40 dB @ 850 nm
40 dB @ 850 & 1300 nm
20 dB @ 1300 nm
Weight 2. 9 lbs (1.3 kg)
Dimensions (H x W x D) 23.4 x 34 x 10.7 cm (9.2 x 13.4 x 4.2 in)
Operating temperature -10 to 50°C
Storage temperature -30 to 60°C
All specifications at 25°C
Ordering Information
Model Includes
All MLP1
models
Optical light source, optical power
meter, protective rubber boots,
adapter cap, 50 and 62.5µm man-
drels, user’s guide, and carrying case.
Test jumpers and connector adapters
are required for operation (purchased
separately). Test jumpers with a variety
of connector styles and fiber types are
available. Adapter caps for most common
connectors may be purchased from AFL
Telecommunications.