User guide
53
SLP5-6D Single-mode Test Kit with Wave ID, Set Reference,
and Data Storage
OLS2-Dual specifications
OPTICAL OLS2-DUAL (SINGLE PORT)
Wavelength 1310 ±20 nm 1550 ±20 nm
Emitter type Laser, Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03
Spectral width (FWHM) 5 nm (max)
Output power
0 dBm
*
Output stability ± 0.05 dB over 1 hour (after 15 min. warm-up)
± 0.1 dB over 8 hours (after 15 min. warm-up)
Tone output 270 Hz, 330 Hz, 1 kHz, 2 kHz
GENERAL
Power 2 x AA batteries, optional AC adapter
Battery life Typical 120 hours, minimum 75 hours
Available adapters SC FC, ST, LC
Operating temperature -10 to 50°C, 90% RH (non-condensing)
Storage temperature -30 to 60°C, 90% RH (non-condensing)
Size (H x W x D) 14.0 x 8.1 x 3.8 cm (5.5 x 3.2 x 1.5 in)
Weight 0.29 kg (0.65 lb)
* Adjustable 2 dB.
All specifications at 25°C.
OPM5-4D specifications
OPTICAL OPM5-4D
Calibrated wavelengths 850, 980, 1310, 1490, 1550, 1625 nm
Detector type Filtered InGaAs
Measurement range +26 to -50 dBm
Tone detect range +6 to -30 dBm
+6 to -25 dBm for 850nm
Wavelength ID range +6 to -30 dBm
+6 to -25 dBm for 850nm
Accuracy*
± 0.25 dB
Resolution 0.01 dB
Measurement units dB, dBm, µW
GENERAL
Power 2 x AA batteries, optional AC adapter
Battery life 300 hours
Operating temperature -10 to 50°C, 90% RH (non-condensing)
Storage temperature -30 to 60°C, 90% RH (non-condensing)
Size (H x W x D) 14.0 x 8.1 x 3.8 cm (5.5 x 3.2 x 1.5 in)
Weight 0.26 kg (0.58 lb)
* Accuracy measured at 25ºC and -10 dBm per N.I.S.T. standards.
All specifications at 25°C