User Guide

PA circuit
Any quantity of normally closed type personal attack button may be wired in series and then
connected to the PA circuit.
Operational in Day and Set, the PA circuit will cause a full alarm condition when activated. PA is
indicated on the control panel as PA.
PA buttons may be fitted near the front door, or in a bedroom.
6 4188-753 issue 1_1/03
Engineering information
PA
+
-
TAMP
+13V 0V
Board
Panel
Panic
Button
Panic
Button
J2
214
3
65
J1