User Guide

Testing the system
Complete the wiring of the system and then:
ÿ
Program the panel.
ÿ
Fully test the system and ensure it is fault
free
ÿ
Fill in the installation log at the back of this
manual and retain if for future reference.
ÿ
Finally explain the operation of the system
to the end user. The Operating Instructions
are attached to the centre of this manual.
Detach them and leave them with the
user.
Key
System indications
- Unset system indication
- Set system indication
Note: The Power LED will give a
flashing indication when there is a mains
supply failure to the panel.
Programs
The panel offers Full Set or selectable Part Set
routine and programmable entry time. As default
the panel is set for Full Set and an Entry time of
30 seconds.
ÿ
Full Set : Arms all of the zones and become
Set as the user leaves the property after the
Exit time of 30 seconds.
ÿ
Part Set : To protect the downstairs areas of
the house at night the Zones 5 and 6 are
omitted from being set as the user goes
upstairs after the Exit time of 30 seconds.
Note: The Part Set assumes Zone 5
and Zone 6 are upstairs zones.
ÿ
Entry time 30 seconds (factory default):
Allows the user to enter the premises and
unset the system within 30 seconds.
ÿ
Entry time 15 seconds : Allows the user to
enter the premises and unset the system
within 15 seconds.
12 4188-753 issue 1_1/03
Engineering information
Powe
r
Day
Powe
r
LED steady On indication
LED Off
Strobe
External Siren
NOTE: In general a flat beep is
an indication of not recognised keyfobs.
Sound description
Internal sound
External devices
LED flashing indication
J6
ON
OFF
ENTRY TIME
PART SET
15S
30S
Board
Panel