User Guide
First Power up
Before power up fit the top cover on to the base
and connect the speaker wires. Leave the cover
in position throughout the reset of the
installation.
a.
Check that the factory fitted links are
connected to terminals unused Zones,
PA, TAMP and T-A.
b. Fit the battery wires to the BATT
terminals on the Board, Red to + and
Black to -.
c. On connecting the battery the system
will now go into alarm condition, the
Tamper LED is lit and the Power LED
gives a flashing indication:
d. Fit the cover to hold down the tamper
spring at the bottom centre of the
board.
e.
Offer a keyfob to the centre depression
on the panel. Note the Tamper LED
and Alarm switches Off and the
LED is lit.
Note: If you do not withdraw the keyfob
after it is recognised by the panel then
you run the risk of entering an undesired
mode of operation.
Mains Connection
The mains power should be connected using a
3 core cable of not less than 0.75mm sq. from a
fused spur to the mains connector inside the
control panel. The 2 A fused spur must be
located close to the control panel.
Note: The mains supply must be
connected by a technically competent
person and according to current IEE
regulations.
Caution: To avoid the risk of electrical
shock you must always totally isolate the
mains supply before opening the control
panel cover(s).
ΓΏ
Mains Input Fuse rating: 125mA, 250V type
T (anti surge) and of a type approved to IEC
127 part 2 sheet III.
On connecting the mains supply to the panel the
power indicator is lit.
(Changes from flashing to steady)
4188-753 issue 1_1/03 11
Logic Six intruder system
N
L
E
Transformer
125mA Fuse
Panel
+-
AC
1.6A
BATTERY
BATT
J4
F1
Board
(red)
+
Black -
12V battery
TA
Alarm
Power
Offer keyfob
to the Panel
and withdraw
Keyfob recognition beep
Accenta
/!
1 2 3 4 5 6
TA
PA
ZONE
Learn
Error
Day
Power
N
L
E
Transformer
125mA Fuse
Panel
+-
AC
1.6A
BATTERY
BATT
J4
F1
Board
(red)
+
Black -
12V battery
2A Fused Spur unit
Dedicated mains supply
from consumer unit.
Day
Power