User Guide
Factory set condition
Keyfob 1 and 2 (supplied) - Learnt
Keyfobs 3 to 8 (optional) - - Require learning
External siren Bell Duration 20 minutes
External siren Bell Delay - - No delay
Full Set
Zone1 ---------Timed
Zone 2 ---------Time inhibited
Zone 3, 4,5&6 ----Immediate
Entry time (timed zone)- 30seconds(default)
(15 seconds via setting DIP switch)
Exit mode is timed - - - 30 seconds
Part set (DIP switch selectable see page 12)
Zone 1,2&3 -----Timed
Zone 4 ---------Immediate zone
Zone5&6-------Omitted zones
Entry time (timed zone)- 30seconds(default)
(15 seconds via setting DIP switch)
Silent Exit mode is timed 30 seconds
Applicable for both full and part set:
Tamper TA 24 hour alarm
Personal Attack PA 24 hour alarm
Security Zones -------Zones 1…6
Zone debounce period - - - 640mS ALL zones
Zone Function
The following are definitions of zone functions:
Timed : This function would be used to protect
the main entry/exit door of the entry route.
Time inhibited (Walk through) : This is a zone
which, on setting the panel, allows access to the
Entry / Exit zone. However, if the panel is set
and an time inhibited zone is triggered before an
Entry /Exit zone then an alarm will be generated
immediately.
Immediate: This is a zone which will, when
entered, go into alarm when the panel is set.
The Entry deviate feature permits an immediate
zone to be activated during the entry period
without causing a full alarm.
Unused : An unused zone that has been linked
out will be ignored by the panel.
10 4188-753 issue 1_1/03
Engineering information