Put the ADU on the mounting flange and use 6 sets of M6 x 20 Hex head screw bolts
with flat washers into the threaded holes of ADU mounting base via the mounting
flange’s holes.
Tighten the flat washers and screw to the antenna unit in order to secure it to the
mounting flange.
Alternatively it can be mounted on the long pole. The physical dimension of a long pole shall
be preferably at 2 meter height with its diameter ranges from Ø35 to Ø 50mm. In addition,
the optional pole mount kit is available for the installation of the ADU onto the long post.
2.2 Installation of BDU
The BDU’s pretty box is unpacked and the following items should be checked whether they
are present:
BDU
1.5 meters Ethernet Cable
1.8 meters DC Power Cable
1 meter Wired Primary Handset with Cradle
Wi-Fi Antenna
Hardcopy Quick Start Guide
CD Format User Manual
The following important notes are to be followed for the selection of a location before
installing the BDU:
The BDU is not water proof and it has to be kept away from water splash.
The ambient temperature and humidity in the selected location must the requirements
given in the BDU’s specification.
Ambient Temperature -25ºC to +55ºC
Relative Humidity Up to 95% at +40ºC.
The BDU shall be kept away from direct sunlight.
The BDU shall be placed away from any high-vibrated and shock areas (for example,
motor engine and generator) as far as possible.
The BDU shall be kept away from any sensitive electronic equipment.
The BDU has to follow the recommended compass safe distance of 1m to prevent
interference to a magnetic compass