H3C S1526 Smart Ethernet Switch Installation Manual Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com Manual Version: T2-IM-20080221-3.
Copyright © 2005-2008, Hangzhou H3C Technologies Co., Ltd. All Rights Reserved No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Hangzhou H3C Technologies Co., Ltd. Trademarks H3C, , Aolynk, , H3Care, , TOP G, , IRF, NetPilot, Neocean, NeoVTL, SecPro, SecPoint, SecEngine, SecPath, Comware, Secware, Storware, NQA, VVG, V2G, VnG, PSPT, XGbus, N-Bus, TiGem, InnoVision and HUASAN are trademarks of Hangzhou H3C Technologies Co., Ltd.
Technical Support soho@h3c.com http://www.h3c.
About This Manual Purpose This document is used to guide you through installing this product. Please read it carefully before your operation. Intended Audience This document is intended for network administrators who know well of the basic network knowledge and network terms. Organization This document is organized as follows: Chapter Content 1 Product Overview This chapter describes the appearance of the H3C S1526 Smart Ethernet Switch (hereinafter referred to as the S1526).
Chapter Content 5 Appendix – Port Properties This chapter describes the port properties, such as the connector type and quantity. Conventions The manual uses the following conventions: I. Symbols Convention Description Caution Means reader be careful. Improper operation may cause data loss or damage to equipment. Note Means a complementary description. Environmental Protection This product has been designed to comply with the requirements on environmental protection.
Installation Manual H3C S1526 Smart Ethernet Switch Table of Contents Table of Contents Chapter 1 Product Overview ........................................................1-1 1.1 Introduction ........................................................................1-1 1.2 Appearance........................................................................1-2 1.2.1 Front Panel ..............................................................1-2 1.2.2 Rear Panel....................................................
Installation Manual H3C S1526 Smart Ethernet Switch Table of Contents Chapter 4 Appendix – Technical Specifications ........................4-1 Chapter 5 Appendix – Port Properties.........................................5-1 5.1 Properties of 10/100Base-TX Ethernet Ports ....................5-1 5.2 Properties of 1000 Mbps Ethernet Ports............................5-2 5.3 Properties of SFP Module Ports ........................................5-2 5.4 Properties of Console Port...............................
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 1 Product Overview Chapter 1 Product Overview 1.1 Introduction H3C S1526 Smart Ethernet Switch (hereinafter referred to as the S1526) is suitable for the networking of small and medium-sized enterprises, and Internet cafe. It provides one console port, 24 × 10/100Base-TX autosensing Ethernet ports and two 1000 Mbps uplink combo ports. Note: z Port 25 and port 26 are 1000 Mbps uplink combo ports.
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 1 Product Overview 1.2 Appearance 1.2.1 Front Panel As shown in Figure 1-1, the S1526 has on its front panel from the left to the right: Power LED, 10/100Base-TX port LEDs, 10/100Base-TX ports, 1000 Mbps uplink combo ports and LEDs, and Console port. Figure 1-1 Front panel The following table presents descriptions of the LEDs on the front panel. Table 1-1 LED descriptions LED Status Description Green The switch is powered on.
Installation Manual H3C S1526 Smart Ethernet Switch LED Link/Act Chapter 1 Product Overview Status Description Green A link is established. OFF No link is established. Blinking Data is being transmitted or received. 1.2.2 Rear Panel The S1526 has one AC power socket on its rear panel, as shown in Figure 1-2.
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 2 Installation Chapter 2 Installation 2.1 Precautions To avoid any damage to the device or human body arising from improper use of the S1526, please follow the precautions and requirements listed below. I. Safety precautions z Unplug the switch before cleaning. Do not clean the switch with wet cloth or liquid. z Do not place the switch near water or in any damp area. Keep water or moisture from entering the switch chassis.
Installation Manual H3C S1526 Smart Ethernet Switch z Chapter 2 Installation Do not open the chassis while the switch is in operation. Do not open the chassis if not necessary, even when the switch is not powered on. II. Installation Environment Requirements The S1526 can be installed in a corridor or a room. The following requirements must be met wherever it is installed in a rack or on a workbench. z There is adequate space (more than 10 cm (0.33 in.
Installation Manual H3C S1526 Smart Ethernet Switch z Chapter 2 Installation Electromagnetic shielding approach is adopted when necessary, such as using shielded port cable. z All port cables are wired indoor, to prevent the ports from any damage that may be caused by overvoltage and overcurrent from lightning strike. 2.2 Installing the Switch Caution: There is a seal on one mounting screw on the chassis of the switch.
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 2 Installation Figure 2-1 Fix the mounting ears 3) Put the switch in a rack tray. Slide the switch along the guide rails to an appropriate place. 4) Fix the mounting ears to the rack posts with screws at both sides. Make sure the switch is securely fixed to the rack tray.
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 2 Installation Note: The mounting brackets are used for fixing rather than weight bearing. In a 19-inch standard rack, the weight of the switch is supported by the tray beneath it. 2.2.2 Installing the Switch on a Workbench In circumstances that a 19-inch standard rack is not available, you can mount the switch on a clean workbench. You are recommended to fasten the feet to the switch before installation.
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 2 Installation 2.3 Connecting the Cables 2.3.1 Connecting Devices to the Switch I. Connect the device to the Ethernet port Use either crossover cables or straight through cables to connect the PC(s) or other device(s) to the Ethernet ports on the switch. II.
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 2 Installation Caution: To avoid eye damages, do not look directly at the laser beam inside the optical fiber. 2.3.2 Connecting the Console Cable Figure 2-5 Connecting the switch to a terminal through console port The switch can be configured through a terminal. Take the following steps to connect the switch and terminal through a console cable.
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 2 Installation Caution: Because the PC serial port is not hot-swappable, DO NOT plug the cable connector into or unplug it from the PC serial port when the switch is powered on. In connecting the PC to the switch plug the DB-9 connector of the console cable to the PC port first, and then plug the RJ-45 connector to the switch port. In disconnecting unplug the RJ-45 connector first and then the DB-9 connector. 2.3.
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 2 Installation 2.4 Starting Up the Switch 2.4.1 Configuring Terminal Parameters 1) Start the PC. In the Windows operating system, click [Start/Programs/Accessories/Communications] to run the Hyper Terminal program on the PC.
Installation Manual H3C S1526 Smart Ethernet Switch MAIN Chapter 2 Installation MENU 1. Modify password 2. Set IP address/Subnet mask/Gateway 3. Reset to default configuration 4. Save current configuration 5. Modify management VLAN 0. Reboot Enter your choice (0-5): Select one option and enter its number after the “Enter your choice (0-5):” to perform the configuration. Table 2-1 Menu item description No.
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 2 Installation Note: For detailed information about the configuration commands, refer to H3C S1526 Smart Ethernet Switch User Manual. 2.4.3 Web Configuration The Web NMS (Network Management System) feature allows the user to manage and maintain the S1526 in a very simple and direct way through Web configuration. Open the Web browser and input the default IP address of the switch http://192.168.0.234 in the address bar.
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 2 Installation Note: For detailed information about the Web configuration, refer to H3C S1526 Smart Ethernet Switch User Manual. Caution: In performing local configuration always set the IP addresses for the PC and the switch in the same subnet (refer to H3C S1526 Smart Ethernet Switch User Manual for the address configuration); in performing remote configuration make sure that the switch is reachable to the PC.
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 3 Troubleshooting Chapter 3 Troubleshooting 3.1 Password Loss If you lose your password for the switch, restore the switch to the factory settings at first by referring to H3C S1526 Smart Ethernet Switch User Manual. Then you can use the default user name “admin” and password “admin” to log in. 3.2 Power System Failure You can know whether or not the power system is working normally by reading the PWR LED on the front panel.
Installation Manual H3C S1526 Smart Ethernet Switch z Chapter 3 Troubleshooting The console cable is in good condition and the terminal (HyperTerminal for example) parameter settings are correct. Refer to section 2.4.1 “Configuring Terminal Parameters” for information about terminal parameter settings. II.
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 4 Appendix – Technical Specifications Chapter 4 Appendix – Technical Specifications Table 4-1 Technical specifications Item Description 24 autosensing 10/100Base-TX Ethernet ports Port Two autosensing 10/100/1000Base-T Ethernet ports Two 1000 Mbps SFP module ports One Console port Physical dimensions (H × W × D) 44 × 440 × 230 mm (1.7 ×17.3 × 9.1 in.) Weight 2.7 kg (6.0 lb.
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 4 Appendix – Technical Specifications Item Description Storage humidity (noncondensing) 10% to 90% System cooling Air cooling 4-2
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 5 Appendix – Port Properties Chapter 5 Appendix – Port Properties 5.1 Properties of 10/100Base-TX Ethernet Ports Table 5-1 Properties of 10/100Base-TX Ethernet ports Item Description Connector type RJ-45 Port quantity 24 Operating rate 10/100 Mbps and auto negotiation Duplex mode Half duplex, full duplex and auto negotiation Network cable connection MDI/MDI-X autosensing Standards supported IEEE 802.3 and IEEE 802.
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 5 Appendix – Port Properties 5.2 Properties of 1000 Mbps Ethernet Ports Table 5-2 Properties of 1000 Mbps Ethernet ports Item Description Connector type RJ-45 Port quantity Two Operating rate 10/100/1000 Mbps and Auto negotiation Duplex mode Half duplex, full duplex and auto negotiation (10/100 Mbps) Full duplex and auto negotiation (1000 Mbps) Network cable connection MDI/MDI-X Standards supported IEEE802.3, IEEE802.3u and IEEE802.
Installation Manual H3C S1526 Smart Ethernet Switch Chapter 5 Appendix – Port Properties Item Standard supported Description IEEE802.3ab 50/125µm multimode optical fiber, transmission distance up to 550 meters (1,804 feet) Media and transmission distance 9/125µm single-mode short-reach optical fiber, transmission distance up to 10 km (6.2 miles) 9/125µm single-mode intermediate-reach optical fiber, transmission distance up to 40 km (24.