- Addtron IP Power 9258 Quick Start & User Manual

_____________________________________________________________________________
IP POWER PAGE 21 OF 24
wgetO -
http://admin:12345678@192.168.0.50/Set.cmd?CMD=SetPower+P60=1+P61=0+P62
=0+P63=1
9. Frequently Asked Questions
Q1: I forgot the password and can not enter the administration page now, what can I do?
A1: Use the username super user when logging in to the webpage and then click OK. Turn the
IP Power off for a few seconds, the turn it back on. The default username of admin and password
of 12345678 will be restored. Note: there is a space between super and user.
10. Manual Control Mode
Before using the manual control function it is necessary to UNPLUG / DISCONNECT all of the 4
outlets. To obtain manual control:
1) Press and hold the ON/OFF button (depicted below) for a full 5 seconds or until a sustained
beep noise is heard this enables manual control mode which can be identified by the
flashing outlet lights
2) The outlet light that is not flashing is the one currently under manual control this outlet can
be turned on or off by pressing the ON/OFF button
3) To select an alternate outlet to control, press the Cycle button (labeled with a circle with
arrows on it)
4) To disable manual control mode, press and hold the ON/OFF button for 5 seconds or until
you can hear a sustained beep noise signifying the deactivation of manual control mode
Cycle (left): Select power outlet to manually control
ON/OFF (right): Press and hold to enable/disable manual control mode, press
to turn on/off the outlet selected by the cycle button
_____________________________________________________________________________
IP POWER PAGE 22 OF 24
11. Remote Browser Control Using a CM/IM4000
The IP Power 9258 is a simple browser controlled power switch, without the security features
needed for open public network connection or remote out-of-band control (dial-in). However when
the IP Power is accessed through an IM42000 gateway or CM4000 console server, the inbuilt
SSH tunneling (SDT) provides secure public access. The IM/CM4000 Management Consoles
also are all preconfigured with the HTTP commands for the IP Power 9258 power strip, so power
strip control is simple:
12. Out-of-Band Access Using a CM/IM4000
The IM/CM4000 gateway provides out-of-band (OoB) access through a dial in modem (or through
an alternate broadband connection for IM4200). To configure the IM/CM4000 for OoB dial-in
access:
1. Connect a modem to the IM/CM4000 console port using a 319004 adaptor with
standard UTP Cat 5 cable (the CM4001 has a DB9 console port, so it will need to use a
31900 and a 319004 adaptor)
2. Configure the IM/CM4000 gateway for OoB dial-in and set up the remote client dial-in
software
3. Configure the IM/CM4000 gateway with the IP Power 9258 as a HTTP accessible Host
(so it can be controlled securely with SDTConnector)
4. Configure SDTConnector so it will access the remote the IM/CM4000 gateway using
dial out, then connect to the IP Power using HTTP