5.7.5.13.2. Default value
In case of G.7231, default value is 1. This means that audio frame is generated
and transmiting RTP packet at every 30ms interval.
Default value is 2 in case of G.729. This means that audio frame is generated at
10ms interval and transmiting RTP packet at 20ms interval.
5.7.5.13.3. Command Mode
Voice-Service setting mode
5.7.5.13.4. Usage Guideline
Generally, if bandwidth is low or congestion is occurred in internet, increase the
max-frame length. At first step, increase the max-frame length as 2 in G.7231,
4 in G.729. If this does not work well, increase the max-frame length as 3 in
G.7231, 6~8 in G.729. Buf, if max-frame is too large, this feature have
transmission delay problem. In cable network that have poor upstream network
environment, this command with qos-control command will enhance the voice
quality.
5.7.5.13.5. Examples
Qos-control and max-frame setting examples for cable modem network.
interface ethernet 0 0
qos-control 128 100
voice service voip
max-frame g729 4
max-frame g7231 2
5.7.5.14. gkip