5.3.12.2. Busyout Action
User can set a specific action such as busyout tone or port-down in a specific
port when VoIP gateway is busyout. If busyout action is set as busyout tone and
situation that meet this condition is occurred, PBX does not call try in this port
because PBX recognizes as busy the state of Internal or external PBX line
connected to gateway port.
In this time, if PBX HUNT function is operated and a call is transferred to external
PSTN line via PBX when gateway port is busy, the perfect PSTN backup service is
possible.
5.4. Configuration Voice Ports
5.4.1. Configuration Voice Ports on the AP200 Gateway
In general, voice port commands define the characteristics associated with a
particular voice port signaling type. Under most circumstances, the default
voice port command values are adequate to configure FXO and FXS ports to
transport voice data over your existing IP network.
STEP Commands Explanation
1
Router#
configure
Enter into configuration setting mode.
2
Router(config)#
voice service voip
Enter into Voice service voip mode
3
Router(config-vservice-voip)#
busyout
monitor
{gatekeeper | voip-interface}
Gatekeeper : busyout setting applied
in gatekeeper.
Voip-interface: busyout setting applied
in voip-interface
STEP Commands Explanation
1
Router#
configure
Enter into configuration setting mode
2
Router(config)#
voice-port
slot-id/port-id
Enter into Voice-port configuration mode
3
Router(config-voice-ports-0/0)#
busyout action
{none | tone | port-down}
None : no action
Tone : busy ton generation
Port-down : port down