User manual
3.7.4 UPS
Select “UPS” function. It will set UPS (Uninterruptible Power Supply)
parameters.
Figure 3.7.4.1
Currently, the system only support s and communicates with smart-UPS function
of APC (American Power Conversion Corp .) UPS. Check details from
http://www.apc.com/ .
First, connect the system and APC UPS via RS -232. Then set up the shutdown
value.
UPS Type
Select UPS Type. Choose Smart -UPS for APC. None
for other vendors or no UPS.
Shutdown
Battery Level
(%)
When value is below the setting level, the system will
shutdown. Setting level to “0” will disable UPS
function.
Shutdown
Delay (s)
If power failure has occurred, and the system cannot
return to the set value on the set period, the system
will shutdown. Setting delay to “0” will disable the
function.
Shutdown
UPS
Select ON. When power on the UPS is almost
depleted, the UPS will shutdown by itself after the
ISC8P2G-S shutdown successfully. After power comes
back on, the UPS will start working and notify system
to boot up. Selecting OFF will not turn off the UPS
automatically.