3.7 Enclosure management
The “Enclosure management” function allows managing the encl osure
information including “SES config”, “Hardware monitor, “S.M.A.R.T. and
“UPS. The enclosure management provide s sensors for different purposes,
such as temperature sensors, voltage sensors, hard disks, fan sensors, power
sensors, and LED status. And because the hardware characteristics are different
among these sensors, different sensors have differen t polling intervals. Below
are the details for the polling time intervals:
1. Temperature sensors: 1 minute.
2. Voltage sensors: 1 minute.
3. Hard disk sensors : 10 minutes.
4. Fan sensors: 10 seconds, when there are continuous 3 times of error,
ISC8P2G-S sends ERROR event log.
5. Power sensors: 10 seconds, when there are continuous 3 times of
error, ISC8P2G-S sends ERROR event log.
6. LED status: 10 seconds.
Figure 3.7.1
3.7.1 SES configuration
SES represents SCSI Enclosure Services, one of the enclosure management
standards. The “SES config” function allows you to enable or disable the
management of SES.
Figure 3.7.1.1
(Figure 3.7.1.1: Enable SES in LUN 0, and can be accessed from every host.)
The SES client software is available at t he following web site:
SANtools: http://www.santools.com/