Figure - 4 Example OOB-07 test stimulus and PUT response, for nominal COMINIT/COMRESET gap
(Test stimulus top, yellow. PUT response bottom, purple.)
2) Detection Tests: Changing the COMINIT/COMRESET gap values only, verify that the PUT continues to
respond to gap values of 459 and 501UI
OOB
(306 and 334ns, respectively)
3) No-Detection Tests: Changing the COMINIT/COMRESET gap values only, verify that the PUT consistently
DOES NOT respond to gap values of 259 and 791UI
OOB
(172.66 and 527.33ns, respectively), with the
exception of unsolicited COMINIT bursts due to ASR (see note above). An example screenshot of typical
PUT behavior appears in Figure 5 below.
Figure - 5 Example OOB-07 test stimulus and PUT response for out-of-range COMINIT/COMRESET
(Test stimulus top, yellow. PUT response bottom, purple.)
Device:
Pass/Fail Criteria
o OOB-07a - Verification of COMINIT response at 459UI
OOB
o OOB-07b - Verification of COMINIT response at 501UI
OOB
o OOB-07c - Verification of no COMINIT response at 259UI
OOB
o OOB-07d - Verification of no COMINIT response at 791UI
OOB