Specifications

SATA-IO Confidential 60
2.15.2. RX-02 : Single-Ended Impedance (Obsolete)
2.15.2.1. Device/Host Expected Behavior
See section 7.2.2.4.2 of Serial ATA Revision 2.6.
See section 7.4.23 of Serial ATA Revision 2.6.
Measurement Requirements
This test requirement is only applicable to products running at 1.5Gb/s. For products which support 3Gb/s,
this test is not required.
Testing of this requirement must be completed during a PHYRDY Interface Power State (see section 8.1. of
SATA Revision 2.6). The amplitude of a TDR pulse or excitation applied to a receiver shall not exceed
300mVpp (-6.48dBm 50 ohms) single ended.
Z
s-eRX
measured to be at least 40 ohms (for products running at 1.5Gb/s)
Pass/Fail Criteria
Both the minimum [RX-02a] and the maximum [RX-02b] results shall be captured
2.15.3. RX-03 : Gen2 (3Gb/s) Differential Mode Return Loss
2.15.3.1. Device/Host Expected Behavior
See section 7.2.2.4.3 of Serial ATA Revision 2.6.
See section 7.4.10 of Serial ATA Revision 2.6.
Measurement Requirements
Calibrate to the end of the SMA cables, but do NOT include (i.e. de-embed) the SMA to SATA PCB and the
SATA connector, so the board and the SATA connector are INCLUDED with the product measurement.
This test requirement is only applicable to products running at 3Gb/s.
Testing of this requirement must be completed during a PHYRDY Interface Power State (see section 8.1. of
SATA Revision 2.6). The amplitude of a TDR pulse or excitation applied to a receiver shall not exceed
300mVpp (-6.48dBm 50 ohms) single ended.
RL
DD11,RX
measured per the values in
Pass/Fail Criteria
Table 9 – RX Differential Mode Return Loss (for products running at
3Gb/s)
Table 9 – RX Differential Mode Return Loss
Test name
Frequency
Minimum (dB)
RX-03a
150MHz-300MHz
18
RX-03b
300MHz-600MHz
14
RX-03c
600MHz-1.2GHz
10
RX-03d
1.2GHz-2.4GHz
8
RX-03e
2.4GHz-3.0GHz
3
RX-03f
3.0GHz-5.0GHz
1