Specifications

SATA-IO Confidential 49
2.12. Phy General Requirements
2.12.1. PHY-01 : Unit Interval
2.12.1.1. Device/Host Expected Behavior
See section 7.2.2.1.3 of Serial ATA Revision 2.6.
See section 7.4.11 of Serial ATA Revision 2.6.
Measurement Requirements
For products which support 3Gb/s, this requirement must be tested at both interface rates (1.5Gb/s and
3Gb/s).
PHY-01a - Mean Unit Interval measured between 666.4333ps (min) to 670.2333ps (max) (for products
running at 1.5Gb/s)
Pass/Fail Criteria
PHY-01b - Mean Unit Interval measured between 333.2167ps (min) to 335.1167ps (max) (for products
running at 3Gb/s)
The values above shall be based on at least 100,000 UIs (covers at least one SSC profile)
2.12.2. PHY-02 : Frequency Long Term Stability
2.12.2.1. Device/Host Expected Behavior
This test is not applicable to products that support SSC.
See section 7.2.2.1.4 of Serial ATA Revision 2.6.
See section 7.4.6 of Serial ATA Revision 2.6.
Measurement Requirements
This test is only run once at the maximum interface rate of the product (1.5Gb/s or 3Gb/s).
The execution of this test must include use of the low pass filter defined within section 7.4.11 of Serial ATA
Revision 2.6.
f
tol
measured between -350ppm and 350ppm
Pass/Fail Criteria
2.12.3. PHY-03 : Spread-Spectrum Modulation Frequency
2.12.3.1. Device/Host Expected Behavior
See sections 7.2.2.1.5 and 7.3.3 of Serial ATA Revision 2.6.
This test requires support for Spread Spectrum Clocking (SSC), which is optional.
See section 7.4.11 of Serial ATA Revision 2.6.
Measurement Requirements
This test is only run once at the maximum interface rate of the product (1.5Gb/s or 3Gb/s).
f
SSC
measured between 30kHz and 33kHz
Pass/Fail Criteria
The value above shall be based on a mean of at least 10 complete SSC cycles