Specifications
SATA-IO Confidential 47
b) If the “Optional Wall” of Figure 28 is present then the distance from the device plug tongue to the wall
shall be 1.58 +/- 0.08 mm.
c) If the “Optional Wall” of Figure 28 is not present then there shall be a minimum of a 1.5 mm keep out
zone from Datum A of Figure 26 to the nearest obstruction.
d) The combined width of the power and signal segments shall be 33.39 +/- 0.08 mm.
e) The separation between the power and signal segments shall be 2.41 +/- 0.05 mm.
2.9. Mechanical – Device - Power Connector
2.9.1. MDP-01 : Visual and Dimensional Inspections
2.9.1.1. Device Expected Behavior
See section 6.1.10.2, Table 6 of the Serial ATA Revision 2.6 specification.
See section 6.3 of the Serial ATA Revision 2.6 specification for slimline ATAPI device requirements.
See section 6.2.4 of the Serial ATA Revision 2.6 specification for uSATA device requirements.
• For a Slimline optical device see section 6.3.4.1, Figure 61 and 62 of the Serial ATA Revision 2.6
specification.
Measurement Requirements
• For 1.8” uSATA devices see section 6.2.4, Figure 54 of the Serial ATA Revision 2.6 specification.
• For all other devices, see section 6.1.10.2, Table 6; section 6.1.2, Figure 26; and section 6.1.3.1, Figures 27
and 28 of the Serial ATA Revision 2.6 specification.
• NOTE : all applicable measurements within this test must be verified as a pass for the overall result of this
test requirement to be reported as a PASS.
Pass/Fail Criteria
For Slimline devices:
a) The thickness of the device plug tongue shall be 1.23 +/- 0.05 mm.
b) If the “Optional Wall” of Figure 62 is present then the distance from the device plug tongue to the wall
shall be 1.58 +/- 0.08 mm.
c) If the “Optional Wall” of Figure 62 is not present then there shall be a minimum of a 1.5 mm keep out
zone from Datum A of Figure 62 to the nearest obstruction.
For 1.8” uSATA devices:
a) The thickness of the device plug tongue shall be 1.23 +/- 0.05 mm.
For all other devices except:
a) The thickness of the device plug tongue shall be 1.23 +/- 0.05 mm.
b) If the “Optional Wall” of Figure 28 is present then the distance from the device plug tongue to the wall
shall be 1.58 +/- 0.08 mm.
c) If the “Optional Wall” of Figure 28 is not present then there shall be a minimum of a 1.5 mm keep out
zone from Datum A of Figure 26 to the nearest obstruction.
2.10. Mechanical – Host - Standard Internal Connector
2.10.1. MHI-01 : Visual and Dimensional Inspections (Informative)
2.10.1.1. Cable Assembly Expected Behavior
See section 6.1.5 of the Serial ATA Revision 2.6 specification.
See section 6.3 of the Serial ATA Revision 2.6 specification for slimline ATAPI device requirements.
• For a Slimline host, see section 6.3.4.2, Figure 72 of the Serial ATA Revision 2.6 specification.
Measurement Requirements
• For all other hosts, see section 6.1.5, Figure 32 of the Serial ATA Revision 2.6 specification.