Specifications

SATA-IO Confidential 33
If a device claims support host interface power management (Word 76 bit 9 set to one in IDENTIFY DEVICE or
IDENTIFY PACKET DEVICE data), upon receipt of a PMREQ_S the following are valid device responses:
respond with between 4 and 16 PMACK primitives and place the device Phy layer into the slumber state
respond with PMNAK until SYNC is received from the host, no device Phy layer power transition shall
occur.
If a host claims support for device interface power management, upon receipt of a PMREQ_S the following are valid
device responses:
respond with between 4 and 16 PMACK primitives and place the host Phy layer into the slumber state
respond with PMNAK until SYNC is received from the device, no host Phy layer power transition shall
occur.
The above responses relative to a host are also required if a host supports device initiated power management.
Setup bus analyzer (or scope) for tracing of bus activity & begin tracing
Measurement Requirements (Device)
Check Word 76 bit 9 in IDENTIFY DEVICE or IDENTIFY PACKET DEVICE (set to one)
If the above is true, then run the following test
o Issue PMREQ_S and receive device response
This requirement must be verified on 10 total sequences
Setup bus analyzer (or scope) for tracing of bus activity & begin tracing
Measurement Requirements (Host)
Issue PMREQ_S and receive host response
This requirement must be verified on 10 total sequences
Verify that PMNAK or between 4 and 16 total PMACKs are received (use trace to verify device response)
Pass/Fail Criteria
Since a single pass/fail result is reported, it must be verified that all 10 test sequences were a pass for the
final result to be a PASS for this test requirement.
2.5.7. IPM-07 : Device default setting for device initiated requests
2.5.7.1. Device Expected Behavior
This test is not applicable to hosts.
See section 13.2.4.3 of Serial ATA Revision 2.6.
If a device claims support device interface power management (Word 78 bit 3 set to one in IDENTIFY DEVICE or
IDENTIFY PACKET DEVICE data), support for device power management shall be disabled (Word 79 bit 3 cleared to
zero in IDENTIFY DEVICE or IDENTIFY PACKET DEVICE data) by default. A device shall not issue Partial/Slumber
requests unless this feature has been enabled by the host as a result of a SET FEATURES command.
Power on device
Measurement Requirements
Check Word 78 bit 3 in IDENTIFY DEVICE or IDENTIFY PACKET DEVICE (set to one)
Check Word 79 bit 3 in IDENTIFY DEVICE or IDENTIFY PACKET DEVICE (cleared to zero)
Issue SET FEATURES (Sector Count = 03h, Features = 10h) to enable device support for initiating power
management
Issue COMRESET and complete OOB sequence
Check Word 79 bit 3 in IDENTIFY DEVICE or IDENTIFY PACKET DEVICE
This requirement must be verified on 10 total sequences