AdderLink X2 Dual Access C .co der .ad ww w w EO VID EO OU T CP U/ KV M SW ITC H A DU m m .co der .
Further information Troubleshooting ........................................................................22 Getting assistance......................................................................22 Radio Frequency Energy ...........................................................24 Installation ...................................................................................5 Stage A - Configuration switch settings ................................5 LOCAL module switches.....................
Welcome Up to 300 metres separation between the local and remote modules via a single Category 5, or higher, cable RS232 SERIAL MOUSE KEYBOARD VIDEO AUDIO Power supply unit X2 X2 DUAL ACCESS DUAL ACCESS LOCAL A special multi-cable simplifies the connection of the keyboard, video, mouse and audio ports* to the LOCAL Extender. REMOTE * The video monitor, mouse, keyboard and audio* peripherals adjacent to the host computer connect to the LOCAL module.
Supplied items - X2 Dual Access Silver Optional power supply connection A DU L CA LO Power and signal activity indicator m r.co dde w.
Supplied items - X2 Dual Access Gold Optional power supply connection S A DU L CA Multi-cable for keyboard, video, mouse and audio connections between computer and LOCAL module LO Connection for local speakers Power and signal activity indicator om r.c dde w.
Installation and operation Installation LOCAL module switches OFF: Normal operation ON: Transparent mode O ON N 1 OFF: Normal operation ON: Flash upgrade/reset password modes 2 34 OFF: Normal operation ON: Reset LOCAL module OFF: Microphone input mode ON: Stereo line-in mode 1 ON 2 3 4 Note: When shipped, all switches are set in the OFF positions and this will produce normal operation with normal microphone input (at the REMOTE module). LOCAL Switch 3 OFF: Microphone input on REMOTE module.
REMOTE module switches (continued) 34 Reserved for future use Determines configuration of hotkeys in conjunction with switch 2 ON 1 2 34 Note: When shipped, all switches are set in the OFF positions and this will produce normal operation. REMOTE Switches 2 and 3 Switches 2 and 3 determine which two keyboard keys (when pressed in unison) are to be designated as ‘hotkeys’.
Stage B - Mounting a module – desk or rack The X2 Dual Access extender modules can be situated on a desk (or floor) or alternatively, for larger installations, mounted within optional rack mount chassis units. Desk mount Apply the supplied self-adhesive rubber feet to the underside of the module(s). • For correct operation, the local and remote units must have ground connections.
ER W O Pink (or maroon) P MIC ER or W O Microphone P Light green E SPK T O or twisted pair cable connector LOCAL Twisted pair connection The link between the LOCAL and REMOTE modules is made via twisted pair cable, specified to Category 5 or higher. Ensure that the total twisted pair cable length (including patch boxes) does not exceed 300 metres for the Silver variant and 200 metres for the Gold variant.
Local speaker connection The Gold variant of the LOCAL module allows a pair of speakers to be connected and used in the vicinity of the host system. Note: A microphone port is provided only at the REMOTE module. The speaker and microphone ports are absent VID from the Silver variant of the X2 EO OU T Dual Access product. CP U/ KV M SW 1 Connect the speaker plug ITC H to the socket labelled .
REMOTE Power supply connection . Power supply connection 1 Insert the IEC connector of the supplied power lead into the corresponding socket of the power supply. Connect the other end of the power lead to a nearby mains socket. Twisted pair, power and serial connections 1 Insert the connector from the twisted pair cable link into the socket marked ‘TO LOCAL’.
ON 1 2 34 Note: When the X2 Gold REMOTE module is rack mounted, the audio connections must be made after the module has been fixed in place. Access is required to the rear and above the rack. Remember to remove the audio connections before attempting to slide out the REMOTE module. Audio connections (Gold only) On the X2 Gold REMOTE module, audio connections are available at the two 3.5” jack sockets mounted on the side (same side as the switch bank).
Operation ER W O REMOTE After two seconds of inactivity from the user currently in control, the modules return to their idle condition and re-instate the keyboard indicators of the locked-out user. Visible image shadows In some installations, you may see some ‘shadows’ to the right of high contrast screen characters. This can be caused by an incorrectly selected sharpness setting and it may be necessary to make adjustments to correct this.
Locking and unlocking the system To enable the video Simultaneously press the currently configured hotkeys (by default, long with . This command will be required to restore the video if along with is used when no password has been set. To disable the video Simultaneously, press the currently configured hotkeys (by default, along with . and ) and and ) To unlock the system 1 Enter the correct password and press .
Special configuration Configuration Entering, using and exiting configuration mode 2 OFF 3 ON Hotkeys = and 2 ON 3 OFF Hotkeys = and 2 ON 3 ON Hotkeys disabled 3 Press the number of the required configuration option, for instance . The ‘Scroll Lock’ indicator will extinguish, leaving the ‘Num Lock’ and ‘Caps Lock’ indicators lit. l rol ScLock m NuLock ps CaLock l rol ScLock m NuLock 4 Press to confirm your option.
To override the REMOTE password 1 Remove power from the REMOTE module. 2 With power to the system and LOCAL module still applied, change LOCAL switch 1 to the ON position. 3 Re-apply power to the REMOTE module. The REMOTE module will go directly into configuration mode so that the old password can be cleared and a new one set. • To clear a password: (within configuration mode) Press followed by and followed by again.
Recognising an Intellimouse-style mouse The Intellimouse format was introduced to support, among other features, the scroll wheel function. If your mouse has a scroll wheel, then it is likely to support the Intellimouse format. If you have a Microsoft mouse, then it will usually state that it is an Intellimouse on its underside label.
Sharpness increase (fine) Brightness decrease Sharpness: Brightness: Sharpness decrease (coarse) Exit image controls and save settings the need for sharpness adjustment If the image controls cannot provide a crisp image If, after adjusting the image controls, the screen image remains fuzzy or has coloured shadows you may need to use the Skew adjustment feature. Please see the next section for details.
Skew adjustment m NuLock ps CaLock l rol ScLock m NuLock 5 Press the and keys to retard or advance the timing of the selected colour channel respectively. On screen you will see a change in the position of the selected colour crosses in relation to the other two.
Miscellaneous settings Reset all configuration options to default states Returns all user configurable options to the settings that are installed at manufacture. The password will be cleared, however, any current image control settings or skew adjustments will not be reset.
To download the files 1 Access the Adder Technology Ltd website (www.adder.com), enter the Support section. Choose the upgrade option that best suits your requirements and download it to your system. 2 Decompress the downloaded file. Depending on the chosen option, there will be a collection of suitable files. As a minimum, there should be the following files: • AUTOEXEC.BAT – directs the computer to run the upgrade programs. • XKVMV2.
Now please follow Stage D. Now please follow Stage E. Stage E - Return all connections to their usual states Once the upgrade process has been completed, perform the following to return the system to its previous state. 1 Ensure that switch 1 on both the LOCAL and REMOTE modules are set to their OFF positions.
No video image is received at the REMOTE module. • Check that the power/activity indicators are lit on the LOCAL and REMOTE modules - if they are not, then there is a power problem. The LOCAL module gains its power either from the computer’s keyboard socket or by using an optional power supply. When keys are pressed or the mouse is moved, check that the indicators flicker – if they do not respond then there could be a twisted pair link problem or a problem with one of the modules.
• Dual Video Transmitter (part code: XDVT) Allows one system to be controlled from two locations or permits a second video channel to be sent to a remote location. Used in conjunction with two X2-Silver or X2 Remote modules. • Rack mount chassis (part code: RMK-CHASSIS) This 19” chassis allows multiple X2-Series modules to be neatly arranged within a standard cabinet. Securing plates and screws are supplied separately for each X2-Series module for use with the rack mount chassis.
Canadian Department of Communications RFI statement This equipment does not exceed the class A limits for radio noise emissions from digital apparatus set out in the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le règlement sur le brouillage radioélectriques publié par le ministère des Communications du Canada.
Adder Corporation, 29 Water Street, Newburyport, MA 01950, United States of America Tel: +1-888-932-3337 Fax: +1-888-275-1117 Adder Technology Limited, Technology House, Trafalgar Way, Bar Hill, Cambridge, CB3 8SQ, United Kingdom Tel: +44 (0)1954 780044 Fax: +44 (0)1954 780081 © 2005 Adder Technology Limited All trademarks are acknowledged. Release 1.0c August 2005 Part No. ADD0057 Documentation by: www.ctxd.