Technical data

Annexes
Severity Level 6, Informational: informational messages
The following messages appear at severity 6:
System has been started
Date & Time have been synchronized to a Network Time Server
User "name" : Outlet (number) of Master M0 has been switched ON
User "name" : Group (number) has been switched ON
Dry Contact Input (number) has been open
Dry Contact Input (number) has been closed
Dry Contact Output (number) has been open
Dry Contact Output (number) has been closed
Mail "subject" has been sent to "name"
Session opened by user "name"
Severity Level 7, Debug: debug-level messages
ePowerSwitch 8XM doesn't generate Severity Level 7.
Pinout of the RJ11 6/6 x-Bus connector
RJ11 6/6 FRONT VIEW
1 2 3 4 5 6
Pin Signal
1 +Vout (+7V / 100mA)
2 GND
3 RS485 – B
4 RS485 – A
5 GND
6 +Vout (+7V / 100mA)
The power supply delivers a voltage of 7V +-10% for a load of 100mA. The output is overload protected and
protected against polarity inversion. The xBus connectors of both ePowerSwitch 8XM and 8XS have the
same features and pinout.
The symmetrical pinout of power output (+Vout) and GND prevents the risk of short circuits if the RJ11
connector is inverted.
58