Specifications
17
g
3 Double-click on each screen representation to set the screen resolution and,
optionally,addascreennameand/orcongureanLEDmonitorindicator:
The screen resolutions are not critical but they enable the CCS4-USB
switch to accurately map the movement of the mouse onto corresponding
movements of the pointer across the screens. The screen names, if used, are
not downloaded to the CCS4-USB switch.
IfyouneedtocongureanLEDmonitorindicator,clicktheLEDSetuptab.
Please see Configuring LED monitor indicators for details.
4 When the screen map is complete and accurately matches the true layout
of the display screens, click File and choose the Save option to store a copy
of the layout. The layout will be stored as a ‘Free-Flow Config file’ with the
extension: .ffc
5 Ensurethattheoptionalupgradecableiscorrectlyinstalled-seeInstalling
the Free-Flow configuration application.
6 To send the configuration, click the Configure menu and choose the Send
Layout to Switch option.
• Ifthedownloadissuccessful,thescreenrepresentationswillbrieyturn
grey and the upper four indicators on the CCS4-USB switch will begin to
scroll across (they will continue to do this while Free-Flow mode is enabled).
• Ifthedownloadisunsuccessful,amessagedialogwillexplainthatitis
‘Unable to communicate with the device’. Check the upgrade cable,
check that the correct serial port is selected and check that the connection
speed shown within the utility matches that of the CCS4-USB switch.
See also Additional
Free-Flow operations
and settings