Specifications
12
g
Checking the CCS4-USB firmware version
In order to operate correctly with the CCS-XB, it is important that your CCS4-
USBhasrmwareversion2.0(orgreater)installed.Ifindoubtyoucancheckthe
firmware version of your CCS4-USB as follows:
1WithyourCCS4-USBpoweredonandwithaUSBkeyboardattached,press
and hold the COMPUTER button for roughly six seconds until the display
shows C.
2Ontheconnectedkeyboard,pressF followed by 1 and then press Enter.
The digits of the firmware version will be shown in sequence with a short
pause between each. For instance 1 > 0 > 2 means that the firmware
version is 1.02 and requires an upgrade.
3 Press E and then press Enter to return the CCS4-USB to normal operation.
If your CCS4-USB unit does require a firmware upgrade, please refer to the
Performing upgrades section.