User guide
17
INSTALLATIONCONFIGURATIONOPERATION
FURTHER
INFORMATION
INDEX
AdderLink Innity browser-based conguration utility
The browser-based conguration utility within all TX and RX units requires a network
connection between the Gigabit Ethernet port of the ALIF 2112T unit and a computer
on the same network. The conguration utility allows you to perform all of the following
functions:
• View/edit the IP network address and netmask,
• Congure separate IP network addresses for video, audio and USB,
• Congure multicast settings (on RX units),
• Congure video bandwidth settings (on TX units),
• View the current video output (on TX units),
• Perform a rmware upgrade,
• Perform a factory reset,
• Enable/disable and congure the VNC network port settings.
To connect a computer system for browser-based conguration
1 Connect a suitable network cable to the Gigabit Ethernet port on the right side of the
ALIF 2112T front panel.
Note: It is also possible to gain access to the browser-based utility via the Teaming port.
2 Connect the other end of the link cable to your network.
3 Similarly, link your computer to the same network.
4 If not already switched on, power up your computer and the ALIF 2112T unit. You are
now ready to use the browser-based conguration utility.
To access the browser-based conguration utility
1 Temporarily connect the ALIF 2112T unit and your computer, as discussed left.
2 Run a web browser on your computer and enter the IP address of the ALIF dual port
that you are using.
The default settings are as follows:
ALIF 2112T RX units
System port 169.254.1.33 169.254.1.32
Teaming port 169.254.1.43 169.254.1.42
Note: Where the port addresses of a unit have been changed and are not known, providing it
is appropriate to do so, perform a manual factory reset to restore the default addresses.
The opening page of the ALIF conguration utility should be displayed:
You can nd further information about the conguration pages within the following
appendix later in this guide:
• Appendix A - Transmitter (TX) unit conguration pages
Use the menu options to choose
the required conguration page
www.adder.com
Link from Ethernet
switch to the System
(Gigabit Ethernet) port
on the right side of the
front panel