AdderView Secure } AVSD1002 (2 port) AVSD1004 (4 port) User Guide 1 2 3 4 ERR PWR
Contents Locations.......................................................................................7 Cabling recommendations...........................................................7 Tamper-evident seals...................................................................7 Links overview..............................................................................7 Mounting......................................................................................8 Making connections.......................
Prior to use, a prospective user of the product should ensure that individuals with the appropriate authority implement the following objectives in the environment where the product is to be used: • The operational environment procedures must ensure that all users are duly authorized and possess the necessary privileges to access the information transferred via the product. This should be implemented physically and in terms of supporting IT infrastructure.
Welcome PC 1 2 3 PC 2 4 PC 3 PC 4 Individually colored indicators provide clear visual feedback about the currently selected channel. Channel switching is by physical button press only, no keyboard or mouse codes are permitted. Hard wired Data Diodes enforce a one-way flow on information. The switching section is hard wired to allow only one channel to be selected at any time. This operation is also closely monitored by separate checking circuitry.
AdderView Secure - features 2 3 4 ERR PWR Switching is controlled solely by the clearly labeled front panel buttons Each selected channel is represented by an individually colored indicator to provide additional visual feedback. 2 port version 2 3 2 1 5V 4 Clear and simple connections All connections are clearly marked to avoid any ambiguity. Full dual link DVI/I video connections are provided and USB connections are used throughout for keyboard and mouse links.
Devices used with the AdderView Secure Keyboard devices Although pointing devices don’t generally process confidential data and are therefore considered to pose a lower risk, you should ensure that the mouse used with the switch is approved against the security policy of your organization and plugged directly into the switch’s USB mouse port with no adapters or converters. The mouse is powered down and reset at every switchover to clear stored states.
Standard items Additional items Rack brackets Including four screws AdderView Secure unit AVSD1002 (2 port) AVSD1004 (4 port) 1 2 3 4 5V, 2A Power supply plus country-specific mains cable RP W R ER Installation CD-ROM 6
Installation The rear panel of the unit is well marked, however, the diagram below offers additional clarity on how best to arrange your connections. You may have noticed that the indicators on the front panel use different colors to represent the various channels. This is done to provide quick and effective visual feedback to the operator. Channel 1 has a green indicator and is traditionally used for the lowest security connection.
Mounting NS OL E 4 1 5V 2.
Making connections Connections to computer systems 2 2.0 A 1 5V 2.0 A 2 At the rear panel of the unit, choose the appropriate channel group (1 to 4) and connect a USB link cable (square type-B plug) to the socket marked 3 Attach the other end of the USB link cable to a vacant USB socket of the appropriate host computer (this will most probably require a rectangular type-A USB plug).
Connections to computer systems (continued) Connecting video inputs 5V 2.0 2 1 5V 2.0 A Digital video input Analog video input A INDOOR USE ONLY 1 To connect a video input 1 Wherever possible, ensure that power is disconnected from the unit and the host computer(s) to be connected.
Connections to user console peripherals To connect speakers 1 Wherever possible, ensure that power is disconnected from the unit and the host computer(s) to be connected. 2 At the far left side of the rear panel, connect the speaker cable to the socket marked ER CO NS OL E NS OL E US CO ER US To connect a keyboard and mouse Note: The AdderView Secure unit can directly accommodate only a USB-style keyboard and mouse.
CO NS OL E ER US ER CO NS OL Digital video display output E To connect a video display 1 Wherever possible, ensure that power is disconnected from the unit and the host computer(s) to be connected. 2 As appropriate, connect either a digital or analog video display to the DVI/I socket on the far left side of the rear panel: • Digital Connect the digital video display cable to the port labeled within the user console section on the rear panel.
Connected EDID information is harvested from the connected video display during unit power on and written to all computer port memories. Not connected Unit retains the EDID information that is already held in the port memories and continues to present them to the attached computers. No new EDID information can be sought from the currently connected video display.
Connection to power supply To connect the power supply 1 Attach the output connector of the power supply (country specific power supplies are available) to the socket on the far right of the rear panel. 2 Important: Please read and adhere to the electrical safety information given within the Safety information section of this guide. In particular, do not use an unearthed power socket or extension cable.
Operation 2 3 4 Tamper-evident seals • The buttons are clearly labeled to eliminate any ambiguity. • Press the appropriate button to select the labeled channel. • When the chosen channel has been connected, the adjacent indicator will illuminate (continuously) to confirm. If the indicator flashes, then the selected computer is either switched off or disconnected. • Each channel uses a differently colored indicator to provide additional visual feedback about the chosen channel.
Further information Video from some computers only • Remember that the AdderView Secure does not convert digital video signals to analog signals and vice versa so it is not generally possible to mix digital and analog inputs. Mixed systems are possible in certain special circumstances but these will require specialist assistance from Adder technical support. Microprocessor malfunction or unanticipated software bugs causing data to flow between ports.
Forced malfunctions due to overloaded signalling. Data transfer by means of common storage. USB ports support keyboard and mouse connections only. The product does not enable a USB memory stick or disk drive to be shared between computers. Unidirectional keyboard and mouse data signalling protects against data transfer across the switch. Timing analysis attacks.
Getting assistance 01954 780081 +1 888 275 1117 • Phone in the UK: in the US: 01954 780044 +1 888 932 3337 in the UK: in the US: • Fax • Email – support@adder.com • Adder Technology website – www.adder.com Check the Support section of our website for the latest solutions and driver files.
• • • • • Adder Technology Ltd warrants that this product shall be free from defects in workmanship and materials for a period of two years from the date of original purchase. If the product should fail to operate correctly in normal use during the warranty period, Adder will replace or repair it free of charge. No liability can be accepted for damage due to misuse or circumstances outside Adder’s control.
Radio Frequency Energy All interface cables used with this equipment must be shielded in order to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances. This equipment generates, uses and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication.
Tel: +65 6288 5767 Fax: +65 6284 1150 Adder Asia Pacific 6 New Industrial Road, Hoe Huat Industrial Building #07-01, Singapore 536199 Adder Corporation, 350R Merrimac Street, Newburyport, MA 01950, United States of America Tel: +1-888-932-3337 Fax: +1-888-275-1117 Adder Technology Limited, Technology House, Trafalgar Way, Bar Hill, Cambridge, CB23 8SQ, United Kingdom Tel: +44 (0)1954 780044 Fax: +44 (0)1954 780081 © 2010 Adder Technology Li