User guide
17
Authentication checking (enhanced models only)
In addition to the anti-subversion scans that occur continuously, enhanced
versions(AVSC1102-XXandAVSC1104-XX)oftheAdderViewSecurealso
provide a trusted mechanism whereby you can confirm their authenticity.
At manufacture, qualifying AdderView Secure units have a unique identity code
conguredwithintheircircuitry.Onrequest,Addercanprovideyouwithan
Authentication Certificate when you provide the following information:
• The8-digitUnitID, and
• The16-digitRequestCode.
Both of these codes are listed on the AdderView Secure unit.
Oncethevalidityofyourrequesthasbeen
confirmed, you will be sent an Authentication
Certificate containing the following:
• Conrmationofthe8-digitUnitID,
• Aunique16-digitQueryCode, and
• AKeyMap which shows a series of
indications that the AdderView Secure
unit must give in response to particular
key presses that you can enter.
Authentication Certificate
Unit ID: 7654-3210
Query code: a1b2-c3d4-e5f6-a7b8
Key Display
0
1
2
3
4
5
6
7
8
9
TouseyourAuthenticationCerticate
1 Apply power to the AdderView Secure unit.
Note: If the unit is already on, remove power, wait five
seconds and then re-apply power.
The green indicator will be on to show that the
keyboard is switched to the internal authentication
channel(alsotheredindicatorsshouldbeperforming
theirintermittentscanprocedure):
.................................
2 Using the attached keyboard, enter the characters:
a u t h e n t i c a t e and press Enter. Note: The video
display is not used during this process - take care to enter
characters correctly.
The first of the four red indicators will begin to flash:
....
3 Enterthe8-digitUnitID code and press Enter.
If the code is correct, the first red indicator will illuminate
and the second will begin to flash:
.................................
4 Enterthe16-digitQueryCode code from the
AuthenticationCerticate(donotenterthedashes)
and press Enter. Take care, you have ten attempts to
enter the correct code - see the section ‘If you make a
mistake when entering’.
If the code is correct, the red indicators will extinguish,
leaving only the green illuminated:
................................
5 Usingtheattachedkeyboard,pressanumerickey(using
the number keys above the main keyboard, not the
numerickeypad)andobservehowthefourredindicators
illuminate in response. Check the pattern against the one
listed on the certificate for the pressed numeric key. You
can check as many of the listed codes as appropriate.
However, if any response does not match the pattern
shown on the certificate, do not use the AdderView
Secure unit and seek immediate advice from Adder
technical support.
If you make a mistake when entering
• Ifyoupressanincorrectkey,presstheEsc key to start the same code again.
• Whileenteringacode,ifyoudonotpressakeyfor30seconds,theunitwill
timeout and you will need to begin whole process again.
• IMPORTANT:YouhavetenattemptstoentertheQueryCodecorrectly(this
is counted each time the Enter key is pressed - using Esc to start the code
againorgoingbeyondthe30secondtimeoutdonotcountasoneofthe
tenattempts).Afterthetenthconsecutiveincorrectattempt,theAdderView
Secure will enter its alert state and will lock out irreversibly.