User guide

 




14
Cascading multiple units
The AdderView CATxIP 1000 units
support up to eight or sixteen
directly connected computer
systems, however, this is by
no means the limit. Instead of
connecting computers to every
output port, you can instead link
AdderView CATx 1000 units (not
IP variants). Thus, each output of
the original AdderView CATxIP
1000 unit can link through to
many more computers connected
to the secondary AdderView CATx
1000 units.
The combination of AdderView
units can be arranged two levels
deep forming a tree, or cascade
arrangement, with computer
systems situated at either level
within that cascade tree.
Note: It is not possible to cascade
two AdderView CATxIP 1000 units
together because they do not
have a Remote User Port on their
front panels. The lower units must
always be the non-IP AdderView
CATx 1000 variants.
The cascade tree
The diagram shows how an AdderView CATxIP 1000 unit and
multiple AdderView CATx 1000 units can be cascaded to two levels.
Computer systems can be connected at any level. The local or global
users can access computer systems situated anywhere within the
cascade tree.
See also
Connecting units in cascade
Addressing computers in a cascade
X200
CAM
CAMCAMCAMCAM
CAMCAMCAMCAM
AdderView CATxIP 1000
Cascade
level 1
Cascade
level 2
AdderView CATx 1000
CAMCAMCAMCAM
AdderView CATx 1000