Adder X200 Extender User Guide PW R TO LO CA L 1 TO LO CA L 2 TE MO RE R DE ® AD
Further information Getting assistance.......................................................................17 Warranty.....................................................................................18 Safety information.....................................................................18 Radio Frequency Energy............................................................19 welcome Connections..................................................................................4 Cable length advice....
Introduction Peripheral connections to each computer system are handled by Computer Access Modules (or CAMs). The long distance link between the CAMs and the common X200 module is made via Category 5, 5e or 6 twisted pair cabling. Special circuitry within the remote module allows you to make adjustments to the sharpness and brightness settings to suit your own preferences.
What you may additionally need PW R TO LO C AL 1 TO LO CA L 2 X200 Module Available with or without audio and skew compensation capabilities TE MO RE Additional Computer Access Module (CAM) modules: USB CAM, no audio Part number: CATX-USB USB CAM with audio Part number: CATX-USBA PS/2 CAM Part number: CATX-PS2 PS/2 CAM with audio Part number: CATX-PS2A SUN CAM with audio Part number: CATX-SUNA contents Supplied items USB keyboard/mouse R DE ® Sun keyboard/mouse AD PS/2-style mouse
Installation & Operation Resolution 1920 x 1200 1600 x 1200 1280 x 1024 X200 without de-skew 50m 100m - X200 with de-skew 50m 200m 300m When used with an AdderView CATx switch It is possible to locate each CAM up to 50 metres from the AdderView CATx switch. This distance must be taken into account when planning the cable run from the X200 to the CATx switch. The total distance from any X200 to any CAM must not exceed 300 metres (or less if an X200 without de-skew is used).
Connections at each CAM (local) unit A range of different connector combinations are made available across the five CAM formats 4 For each cable run, attach the cable connector to the socket of the CAM. The other end of each cable run will attach to the remote X200 module.
Connections at the X200 (remote) module 3 Attach the connector of each cable run leading from the CAMs (and/or AdderView CATx switch) to the TO LOCAL 1 and TO LOCAL 2 sockets of the X200. 1 Place the X200 module adjacent to the remote user location. 2 Attach the video monitor, USB keyboard, USB mouse and speaker connectors to the sockets of the Adder X200 module.
X200 module switches 34 Reserved for future use Determines configuration of hotkeys in conjunction with switch 2 ON 1 2 34 Note: When shipped, all switches are set in the OFF positions and this will produce normal operation. Switches 2 and 3 Switches 2 and 3 determine which two keyboard keys (when pressed in unison) are to be designated as ‘hotkeys’.
Operation To disconnect from both systems (using the keyboard) Press the currently configured hotkeys (by default, and ) along with To select a system using a 3 button mouse You can use a 3 button mouse to change between channels. A 3 button mouse can either have three distinct buttons or alternatively be a ‘wheel mouse’ where the central scroll wheel may be depressed. Notes: You first need to enable mouse switching - see Mouse switching control.
Special configuration Hotkeys are two normal keyboard keys that, when pressed simultaneously with a third key, signal to the X200 module that you are sending a message specifically to it and not to the connected computer. The hotkeys are ordinarily and , while a third keypress determines what you want the module to do.
To clear a password (and restore factory default settings) 1 Connect the X200 module to a computer in the same manner as you would to carry out a flash upgrade - see ��Performing flash upgrades. 2 While power is applied, set the X200 upgrade switch SW1 to its ON position. 3 Remove power from the X200 unit and then re-apply power.
Recognising an Intellimouse-style mouse The Intellimouse format was introduced to support, among other features, the scroll wheel function. If your mouse has a scroll wheel, then it is likely to support the Intellimouse format. If you have a Microsoft mouse, then it will usually state that it is an Intellimouse on its underside label.
To apply remote user video compensation Video compensation is controlled by the X200 module and it maintains independent compensation settings for each of its two ports. Note: When used with an AdderView CATx switch, also see the section opposite. 1 First select the port that you wish to adjust: On the keyboard that is connected to the X200 remote module, simultaneously, press the hotkeys (by default, and ) along with for the first port or for the second port.
Video skew adjustment (X200AS models only) 2 On the keyboard connected to the X200AS, simultaneously, press the hotkeys (by default, and ) along with to enter configuration mode. The three keyboard indicators (‘Num Lock’, ‘Caps Lock’ and ‘Scroll Lock’) will now begin to flash in sequence. welcome installation & Creating a �������������������� skew test pattern i Run any image creation/editing application, such as the Paint program supplied with Windows.
Miscellaneous settings NuLock ps CaLock l rol ScLock m NuLock ps CaLock l rol ScLock m NuLock 4 Press the and keys to retard or advance the timing of the selected colour channel respectively. On screen you will see a change in the position of the selected colour crosses (or colour bars) in relation to the other two. Reset all configuration options to default states Returns all user configurable options to the settings that are installed at manufacture.
Performing flash upgrades 5 On the computer, select the KVMUploader icon to run the upgrade utility. The KVM Firmware Uploader dialog will be displayed: contents The Adder X200 modules and CAMs are fully reconfigurable via flash upgrades using the KVM Firmware Uploader utility. During the upgrade you will be required to connect the X200 module directly to the serial port of a computer system using an optional cable (Adder part number: CAB-9DF-RJ9-2M).
Check also that the ‘New firmware version’ is greater than the ‘Current firmware version’. contents welcome installation & Issues to consider when performing flash upgrades The upgrade program rewrites the Adder X200 firmware code. If the upgrade process is interrupted then the X200 will have invalid code and will not be able to operate. It is therefore good practice to ensure that the upgrade process is always fully completed.
Further information • Adder Technology website – www.adder.com Check the Support section of our website for the latest solutions and driver files. contents Getting assistance • Phone in the UK: in the US: 01954 780044 +1 888 932 3337 installation & 01954 780081 +1 888 275 1117 special configuration in the UK: in the US: further information • Fax welcome • Email – support@adder.
contents welcome installation & • For use in dry, oil free indoor environments only. • Do not use to link between buildings. • Ensure that all twisted pair interconnect cables are installed in compliance with all applicable wiring regulations. • Do not connect CATx link interfaces (RJ45 style connectors) to any other equipment, particularly network or telecommunications equipment. • Warning – the power adapter contains live parts.
Canadian Department of Communications RFI statement This equipment does not exceed the class A limits for radio noise emissions from digital apparatus set out in the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le règlement sur le brouillage radioélectriques publié par le ministère des Communications du Canada.
contents Tel: +65 6288 5767 Fax: +65 6284 1150 installation & Adder Asia Pacific 6 New Industrial Road, Hoe Huat Industrial Building #07-01, Singapore 536199 special configuration Adder Corporation, 29 Water Street, Newburyport, MA 01950, United States of America Tel: +1-888-932-3337 Fax: +1-888-275-1117 further information Adder Technology Limited, Technology House, Trafalgar Way, Bar Hill, Cambridge, CB3 8SQ, United Kingdom Tel: +44 (0)1954 780044 Fax: +44 (0)1954 780081 welcome © 2008 A