User guide
 
24
To zero the skew adjustment dials
When supplied, the two skew dials are set in 
their neutral positions. i.e. no delay to either 
of its colours. However, if the module has 
been previously used and adjusted then you 
may need to relocate the zero point. There are 
no setting markers around the two skew dials 
and the dial itself does not have a pointer. 
1 Insertasmallscrewdriverintotheskew
dial and twist it all the way anticlockwise. 
Notethepositionofthedialwhenit
reaches its end point.
2 Rotate the screwdriver fully clockwise and 
again note the endpoint position of the 
dial.
3 Nowrotatethescrewdriveranticlockwiseuntilthedialreachestheposition
that lies midway between the two end points. This is the neutral position. 
4 Repeat this procedure for the other skew dial, if necessary.
0
(no compensation)
Max Max
To adjust the skew compensation
Your chances of achieving a successful skew compensation adjustment will be 
improved if you do the following:
• Ensurethatyouhaveaclearviewofoneorbothdisplayscreens,
• DisplayasuitableRGBtestpattern,eitherthesupplied pattern or a self-
created version,
• Useascrewdriverofanappropriatesizetoadjustthedials,
• Beginwithbothskewdialsintheirneutralpositions-ifthemodulehas
been previously used and skew adjusted for an alternative installation, zero 
thedialsasdescribedinthesection‘Tozerotheskewadjustmentdials’left.
0
(no compensation)
Skew RG Skew GB
0
(no compensation)
Delay
RED
Delay
GREEN
Delay
GREEN
Delay
BLUE
1 Turn the SKEW RG dial clockwise or anticlockwise until you observe that the 
red and green colours are aligned. 
2 Turn the SKEW GB dial clockwise or anticlockwise until you observe that the 
green and blue colours are aligned. 
3 Your actions in step 2mayaltertheRed/Greenalignment.Ifso,gobackto
the SKEW RG dial and turn it clockwise or anticlockwise until you observe 
that the Red and Green colours are aligned, at which point all of the colours 
will be aligned. 