User guide

 


19

Switch settings - AV204T/AV208T only
The AdderLink AV204T and AV208T transmitter modules are both equipped
with 10-way mini switches to allow quick configuration of various items. For
normaloperationinthemajorityofcases,allswitchesshouldbeOFF.
Switch 1 is used when upgrading the internal firmware and switches 2 to 10 are
all related to various aspects of serial communications.
Note: All switch settings must be selected before power is applied.
ADDER
®
TRANSMITTER
LINK 5 LINK 6 LINK 7 LINK 8
LINK 1
POWER
LINK 2 LINK 3 LINK 4
DERLINK
www.adder.com
208
1
2
3
ON
4
5
6
7
8
9
10
Operation mode (SW1 - select before powering on)
SW1 OFF Normal operation
SW1 ON Upgrade mode
Serial communications data byte length (SW2)
SW2 OFF 8-bits per character
SW2 ON 7-bits per character
Serial communications stop bits (SW3)
SW3 OFF 1 stop bit
SW3 ON 2 stop bits
Serial communications parity checking (SW4 & SW5)
None Odd Even
SW4 OFF ON ON
SW5 OFF OFF ON
Serial communications baud rate (SW6, SW7 & SW8)
19200 9600 2400 1200
SW6 OFF ON OFF ON
SW7 OFF OFF ON ON
SW8 OFF OFF OFF OFF
Serial communications hardware handshaking (SW9)
SW9 OFF Software handshaking only
SW9 ON Hardware handshaking enabled (RTS/CTS)
Compatibility mode (SW10 - select before powering on)
SW10 OFF AV200 mode (RS232 enabled)
SW10 ON AV100 mode (RS232 disabled)
Important
• ItisessentialthatthesourcePC,allAV204T/AV208Tmodulesandall
connected displays are configured to use the same serial communication
settings. The AV200T, AV200R and AV201R modules all auto-sense the serial
configuration and do not need to be set.
• WhenswitchesSW2toSW10areallOFF,theAVmoduleissettoexpectthe
following serial port configuration: 19200 baud, 8-bit data byte, 1 stop bit,
no parity checking, software handshake.