FRONT PANEL INDICATORS
To assist with operational checks and troubleshooting, the front panel provides the
following indicators:
• ADM On when an administrator is logged in. Flashes when an
administrator is accessing the system.
• USR On if there are any connections between channels/receivers.
Flashes when a user is accessing the system.
• UNC Uncongured RX or TX units are online
• ETH1 On when connected, ashes with network activity
• ETH2 On when connected, ashes with network activity
• PWR On when power is applied
INSTALLATION REQUIREMENTS
• A.I.M. v2.0 or above requires all ALIF units to be at rmware version 2.0 or greater.
• A.I.M. v3.0 requires all ALIF units to be at rmware version 3.0 or greater.
• When upgrading an ALIF/A.I.M. network from rmware versions 2.0 to 3.0, proceed
in the following order: First upgrade the A.I.M. to its version 3.0 rmware; it will
subsequently report that it can no longer support the ALIF devices. Next upgrade the
ALIF devices to their v3.0 rmware.
• On the network switch(es) that have A.I.M. server(s) attached, ensure that the portfast
option is enabled on each port to which an A.I.M. unit is connected. Where portfast
is not enabled, if a second A.I.M. is added for redundancy, this could result in a mis-
congured back up server.
• If an existing A.I.M. server must be replaced, follow the important advice given within
Appendix C (Swapping out an A.I.M. server).
• When conguring the installation for multicasting (and to improve overall
performance), the network switch(es) being used must support a minimum of IGMP v2
snooping. For faster performance use switches that support IGMP v3.
• In order to display video resolutions that use a horizontal video resolution of 2048
pixels, the network switch must have support for Jumbo packets.
• Please also see Appendix A - Tips for success when networking ALIF units.