AdderView CATxIP 5000 User Guide LOC REM VNC 100 LNK PWR www.adder.
Mounting......................................................................................8 Connections..................................................................................9 Local user................................................................................10 Global users (IP network port)..............................................11 Computer system (via CAM)..................................................12 Power in connection....................................................
Getting assistance.......................................................................49 Troubleshooting.........................................................................49 Appendix 1 – Local setup menus...............................................50 Functions................................................................................51 User Preferences....................................................................52 Global Preferences..............
Index Appendix 7 – Cascading multiple units.....................................82 Connecting units in cascade.............................................83 Addressing computers in a cascade.................................84 Using cascaded computers................................................84 Appendix 8 – Cable and connector specifications....................85 AdderView CATxIP 5000 to power switch cable .................
LOC REM VNC 100 IP network/ Internet LNK PWR www.adder.com Power switch CAM CAM CAM formats The CAMs are available in different formats to support all common types of systems, which can easily be mixed within a multi-format configuration. CAM CAM CAM CAM ADDER.NET keeping control For larger installations, the ADDER.NET application manages your hosts, devices and users to enable quick configuration and secure, flexible operation. A copy is included with every AdderView CATxIP 5000 unit.
Global User Global User Global User Global User Global User Global User Global User Global User Global User Global User Global User Global User Local User IP network/ Internet LOC REM VNC 100 Local User Local User ADDER.NET IP network/ Internet LNK PWR www.adder.com LOC REM VNC 100 LNK PWR LOC REM VNC 100 LNK PWR www.adder.
AdderView CATxIP 5000 features - front and rear REM VNC 100 LNK PWR IP network port The port by which global users are linked to the AdderView CATxIP 5000 unit. This intelligent Ethernet port can automatically sense whether it is attached to a 10Mb or 100Mb network. www.adder.com Indicators These six indicators clearly show the key aspects of operation: • LOC Keyboard or mouse data are being received from the local console. • REM Keyboard or mouse data are being received from the remote console.
What’s in the box Power adapter and countryspecific power lead VN C 100 LN K PW R ww w.a dd er.c om CD-ROM x 2 Four self-adhesive rubber feet RE M What you may additionally need Computer Access Modules One required per connected computer. There are three different formats, depending on the required computer connections: PS/2-style Connectors:Analog video, PS/2-style keyboard and PS/2-style mouse.
Mounting The AdderView CATxIP 5000 units offer three main mounting methods: • Supplied four self-adhesive rubber feet • Optional single unit rack brackets • Optional double unit rack brackets Single unit rack brackets These two brackets (plus four screws), extend the size of the AdderView CATxIP 5000 so that it fills the full width of a 1U rack slot.
Connections The AdderView CATxIP 5000 provides a great deal of flexibility in its configurations. This chapter details the various connections that can be made to achieve the required installation.
POWER IN CAM COMPUTER SYSTEM POWER SWITCH AdderView CATxIP 5000 rear panel OP TIO NS 5V 4.0 A 16 1 12 CO MP 1 UT From video monitor IP To connect the local user port 1 Position a suitable video monitor, keyboard and mouse in the vicinity of the AdderView CATxIP 5000 unit such that their cables will easily reach. 2 Attach the video monitor, keyboard and mouse connectors to the sockets, collectively labelled as USER CONSOLE, at the rear of the AdderView CATxIP 5000 unit.
To connect the IP network port for global users 1 Depending upon where in the network the AdderView CATxIP 5000 is being connected, run a category 5, 5e or 6 link cable from the appropriate hub or router to the AdderView CATxIP 5000 unit. 2 Connect the plug of the link cable into the IP port on the front panel of the AdderView CATxIP 5000 unit. 3 Configure the network settings as appropriate to the position of the AdderView CATxIP 5000 within the network - see Networking issues for details.
A range of different connector combinations are made available across the five CAM formats USB keyboard/mouse Sun keyboard/mouse Yellow indicator - signal activity Computer Access Module Category 5, 5e or 6 cable to AdderView CATxIP 5000 Note: CAMs derive power from the computer system via either the PS/2-style keyboard connector, USB or SUN connector.
Power in connection LOCAL USER GLOBAL USERS IP 2 Connect the IEC connector of the supplied country-specific power lead to the socket of the power adapter. POWER IN POWER SWITCH AdderView CATxIP 5000 rear panel OP TIO 5V 4.0 A NS 16 1 12 CO output lead from power adapter MP 1 UT 3 Connect the power lead to a nearby main supply socket. Note: Both the AdderView CATxIP 5000 and its power supply generate heat when in operation and will become warm to the touch.
The options port of the AdderView CATxIP 5000 can be used to connect to one or more IP optional power control units. This allows you to POWER control the mains power being supplied to the IN connected computer(s) so that an authorised CAM user can, if necessary, perform a complete remote cold reboot on a failed system. COMPUTER POWER SYSTEM SWITCH The control connector of the first power switch is attached, via serial cable, to the rear panel of the AdderView CATxIP 5000.
13 8 11 10 9 4 15 14 13 8 11 10 9 4 7 6 5 5V 4.0A 12 16 COMPUTER CONNECTIONS 3 2 1 7 6 5 3 2 1 COMPUTER CONNECTIONS OPTIONS 5V 4.0A 12 COMPUTER CONNECTIONS COMPUTER CONNECTIONS Master AdderView CATxIP 5000 Notes It is recommended that the second CAM in each pair is a USB-type and that it is plugged to a vacant USB port on the host computer to derive its power. Pairs of CAMs can be strapped back-to-back with cable ties to create a tidy installation.
Remote switching control 12 CO MP 1 UT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 0 (video off) 10 20 30 40 50 71 72 73 74 75 11 21 31 41 51 12 22 32 42 52 13 23 33 43 53 14 24 34 44 54 15 25 35 45 55 16 26 36 46 56 17 27 37 47 57 18 28 38 48 58 19 29 39 49 59 1A 2A 3A 4A 5A 16 1 Host computer port/channel Local user VNC user 1 VNC user 2 VNC user 3 VNC user 4 NS 1B 2B 3B 4B 5B 1C 2C 3C 4C 5C 1D 2D 3D 4D 5D 1E 2E 3E 4E 5E 1F 2F 3F 4F 5F 5V 4.
Configuration When setting up a new installation, the following stages are recommended: 1 Enable the general ‘Security’ option. With security disabled (default setting), a local or remote user attached to the AdderView CATxIP 5000 will have full and unrestricted access to all computers and all AdderView CATxIP 5000 settings. In larger installations, you are strongly recommended to enable security and set up individual user accounts with access privileges.
If the Login is shown, enter your ‘admin’ Username and Password - or press twice if none have yet been defined.
Your Login name 2 Press Green - accessible Red - inaccessible Orange - an inconsistency related to a cascade linked host has been detected - More [+] Port numbers Connection status Main Menu to display the main menu: Menu layout The various menu options are arranged as shown here For a description of each option within the Configuration menus, see Appendix 1 for more details.
To change the hotkeys The AdderView CATxIP 5000 unit uses and as its standard hotkeys. These can be changed if they clash with other software or hardware within the installation. 1 Display the Main menu. 2 Highlight ‘Setup Options’ and press . 3 Highlight ‘Hotkeys’ and press (or click one of the arrow buttons) to select the required hotkey combination. The options are: Ctrl+Alt, Ctrl+Shift, Alt+Shift, Alt Gr, Left+Right Alt, Left Ctrl+Alt or Right Ctrl+Alt.
4 ������������������������������������ Highlight ‘Reset Configuration’ and press . The Reset Config warning will be displayed� 5 ���������������������������� Highlight ‘Reset’ and press .
Clearing IP access control Click here to remove all IP access restrictions To clear IP access control 1 From a local keyboard (not accessible from a global keyboard), log on as the ‘admin’ user. 2 Press (hotkeys can change). 3 Press to select the More Menus. 4 Select ‘Configuration’. 5 Select ‘Network Configuration’.
To configure the unit from a global user location 1 Use either the VNC viewer or a standard web browser to make remote contact with the AdderView CATxIP 5000 – see Global user access for more details. 2 If the username entry is not blanked out, enter ‘admin’. Then enter the admin password or the username / password of a user with admin privilege (if no password is set, then just press ).
Viewer encryption settings The web browser viewers and VNC viewers (of level 4.0b5S or higher) offer four encryption settings: • Always on - This setting will ensure that the link is encrypted, regardless of the AdderView CATxIP 5000 encryption setting. • Let server choose - This setting will follow the configuration of the AdderView CATxIP 5000. If the AdderView CATxIP 5000 has ‘Always on’ or ‘Prefer on’ set, then the link will be encrypted.
Networking issues Internet Internet Every network setup is different and great care needs to be taken when introducing a powerful device such as the AdderView CATxIP 5000 into an existing configuration. A common cause of potential problems can be in clashes with firewall configurations. For this reason the AdderView CATxIP 5000 is designed to be intelligent, flexible and secure.
When a web server is also on the local network Port 80 is the standard port used by web (HTTP) servers. If the AdderView CATxIP 5000 is situated within a local network that also includes a web server or any other device serving port 80 then, if you want to use the web browser interface from outside the local network environment, the HTTP port number of the AdderView CATxIP 5000 may need to be changed.
DNS addressing As with any other network device, you can arrange for your AdderView CATxIP 5000 to be accessible using a name, rather than an IP address. This can be achieved in two main ways: • For small networks that do not have a DNS (Domain Name System) server, edit the ‘hosts’ files on the appropriate remote systems. Using the hosts file, you can manually link the AdderView CATxIP 5000 address to the required name.
Addressing When the AdderView CATxIP 5000 is situated alongside the firewall, it will require a public static IP address (i.e. one provided by your Internet service provider). More addressing information: Discover DHCP-allocated addresses DNS addressing Ensuring sufficient security The security capabilities offered by the AdderView CATxIP 5000 are only truly effective when they are correctly used.
Example 1 To switch ON port 5 of switch box 2, the code would be as follows: • Power sequence: P25=1\0D Example 2 To switch OFF port 8 of switch box 3, the code would be as follows: • Power sequence: P38=0\0D For details about operating this feature, see Power switching control within the Operation chapter. 6 Enter the Power control sequences in the Power On and Power Off fields 7 Click OK to close the dialog and then click the Save button in the main Host Configuration window to store the details.
Upgrading AdderView CATxIP 5000 models 8 Click the ‘Browse’ button and locate the .bin upgrade file that you downloaded earlier. Click the ‘Upload file’ button. The AdderView CATxIP 5000 will next show the following screen: 9 Select which portion of the AdderView CATx IP that you wish to upgrade: • Tick the ’Main’ option to upgrade the AdderView CATxIP 5000 unit itself. • Tick one or more of the CAM options to include them in the upgrade process.
Accessing the AdderView CATxIP 5000 The front panel indicators The AdderView CATxIP 5000 provides two ways to gain access: • Local user access, or • Global user access via IP network link. LOC REM VNC 100 IP Indicators • LOC Keyboard or mouse data are being received from the local console. • REM Keyboard or mouse data are being received from a remote (global) viewer. LOC REM VNC 100 • VNC Indicates that a global user is connected and active.
Local user access If the above login prompt is not displayed, you are either already logged in to the AdderView CATxIP 5000 unit, or the security features have not been enabled. In such cases see ‘To view this menu at any time’ below. 2 Enter your username and password.
The Select Host menu – here you can select computers by name. 2 Use the and keys (or the scroll wheel of an IntelliMouse) to highlight the required computer name. Alternatively (for large configurations), press to perform an alphabetical search for a particular port name. You can also use the PgUp and PgDn keys to move up or down a full page of list entries at a time, or press the Home and End keys to quickly move to the beginning or end of the list, respectively.
At any time you can view a list of which users are logged-in and the host computers that they are currently accessing. This can be particularly useful if you find that the host to which you need access is already being viewed in private by another person. To view the show all users list 1 From a local keyboard, log on as a standard or ‘admin’ user. 2 Press (hotkeys can change). 3 Press to show the Main Menu. 4 Select ‘Functions’ and press . 5 Select ‘Show All Users’ and press .
To enable/disable the confirmation box 1 Display the Select Host menu in one of two ways: • By simultaneously pressing and then releasing , or • By pressing the middle and right buttons of a three button mouse. If you are not already logged in, do so now. 2 Press to select ‘More menus’. 3 Highlight the ‘User Preferences’ option and press to select. 4 Highlight the ‘Confirmation Box’ option and press to select ‘Enabled’ or ‘Disabled’, as required. 5 Select the ‘Save’ button to return to the previous menu.
Orange dot indicators in the Select Host menu Within the Select Host menu, each listed host has a coloured dot associated with it to indicate its general status: Green for accessible and Red for inaccessible. There is, however, a third state where the dot turns Orange. An orange dot against a host entry indicates that an inconsistency relating specifically to cascaded hosts.
Global user access LOC REM VNC 100 LNK PWR www.adder.com CAM COMPUTER SYSTEM What will I see when I first login? When you login to a VNC session, the result that you first see will depend on the status of your username account: • If you are using your username for the first time then no host will be initially selected. Click the Hosts button to view a list (see Host selection for details). • If you have previously been logged in, the last host computer that you viewed will be shown.
A connection details dialog will be displayed: Enter the AdderView CATxIP 5000 address here and click OK If required, select the encryption mode - MORE [+] The AdderView CATxIP 5000 has the ability to distribute its own VNC viewer application. To download the VNC viewer 1 Open your Web browser. 2 Enter the network address where the AdderView CATxIP 5000 is situated (in the form: http://192.168.0.3) and make the link.
Global user access via web browser You can use a standard Web browser (supported versions) to gain access to the AdderView CATxIP 5000 and its host computer(s). As soon as you make contact with the AdderView CATxIP 5000 it will begin downloading a small Java application to your browser, which will be used only for the duration of your connection. To access via your web browser 1 Launch your standard Web browser as usual.
Using the viewer window When using the viewer window Controls Displays a menu of options concerning keyboard, video and mouse operation. Power Click to access the power on/off options for the current host computer. Dialogue area Indicates your username and the host system that you are currently viewing. This area can also display other messages. How do I escape from full screen mode? Press the F8 button. This button is changeable but is most often set to F8.
Mouse pointers Host selection For the browser viewer, the local cursor is a typical arrow: To select a host 1 Click the Hosts button to display a list of computers. 2 Click the required computer name to view and control it. You can use the List Order option to determine whether the hosts are listed by their entry number or alphabetically. See Appendix 2 - Host configuration for details about programming new hosts into the AdderView CATxIP 5000 (‘admin’ user status required).
Upon completion an information dialog will explain the results: To re-synchronise the mouse 1 Use the Hosts button to select the required computer. 2 Click the button and then click OK in the subsequent pop-up message. Note: If you find that this doesn’t work, you may need to perform a mouse calibration again. If you find that your local mouse pointer and that of the host are not correctly synchronised, use this feature to re-align their movements.
Controls Resync Mouse This option has the same effect as the button on the menu bar and resynchronises the local and remote mouse pointers. Refresh Screen This option refreshes the whole screen image to remove any artifacts from moved screen items. This is useful when using very low refresh rates on slow speed communication links.
When entering codes: + means press down the key that follows – means release the key that follows +– means press down and release the key that follows * means wait 250ms (note: if a number immediately follows the asterisk, then the delay will equal the number, in milliseconds) It is automatically assumed that all keys specified will be released at the end, so there is need to specify -Ctrl or -Alt if these keys are to be released together. See Appendix 9 for a list of key sequence codes that can be used.
Horizontal Position Determines the horizontal position of the host screen image within the viewer window. Vertical Position Determines the vertical position of the host screen image within the viewer window. Custom Modes See the next page. Advanced See the next page. Brightness & Contrast The red, green and blue constituents of the brightness and contrast can be set individually. Alternatively, use the Auto button on the right side to automatically optimise these for the current host and connection speed.
Advanced Video Settings This option contains video signal settings that do not normally need to be adjusted. Pixel Format Determines the colour depth and data required to represent each video pixel. Reduced Blanking The Reduced Blanking option can be enabled when using flat panel display monitors and helps to save bandwidth without any loss of performance.
VNC hotkey selection Selects port 2 • • • • then Selects port 10 Note: When entering multiple digit addresses as above, keep and pressed down until all other numbers have been entered. Selects no host Displays the Host Selection menu so that you may choose a host by name. in and Standard hotkeys The range of hotkey combinations are as follows: Note: If your hotkeys have been changed, substitute them for the examples given here.
Supported web browsers The following web browsers have been tested and found to work correctly with AdderView CATxIP 5000. Windows • Internet Explorer 5.50 and above, with Microsoft [Java] Virtual Machine (release 5.50). with Java Runtime Environment 1.3 or above. Linux • Netscape 4.61 and above, with Java Runtime Environment 1.1 or above. • Opera, with Java Runtime Environment 1.1 or above.
Further information If you are still experiencing problems after checking the list of solutions in the Troubleshooting section then we provide a number of other solutions: • Adder Technology website – www.adder.com Check the Support section of our website for the latest solutions and driver files. • Email – support@adder.
Appendix 1 – Local setup menus The full set of options are only available to the Admin user. All other users will see only the Functions and User Preferences options.
Functions Power Control The options within this section are usable only when the AdderView CATxIP 5000 is used in conjunction with one or more external power switch units and when valid power switching strings have been registered for the currently selected host. For more details see: power switching connections, configuration or operation (via menu) Switch Computer ON Select this option to power on one or more computers.
User Preferences Screen Saver Settings: Blank, Moving Logo You can select the type of screen saver. If you select BLANK then the screen will blank completely. If you select Moving Logo then a small Adder logo will bounce around the screen. Confirmation Box Settings: Disabled, Enabled When enabled, a confirmation box is displayed on screen for three seconds after a computer is selected. The confirmation box indicates the current user port and user name, the selected computer and the connection status.
Global Preferences Mouse Switching Settings: Enabled, Disabled The computer channel can be switched using a three button mouse or IntelliMouse. Pressing the central button or wheel button together with the left hand mouse button will cause the AdderView CATxIP 5000 to switch to the next available computer. When mouse switching is enabled, you can still use the middle button on its own to control applications.
Setup Options Logon Security Settings: Disabled, Enabled With security disabled there is no requirement for users to log-in to the system. All users have full access to all the connected computers and full administration rights. With security enabled, users are required to log-in to the AdderView CATxIP 5000. Each user is allocated access rights to computers by the system administrator and they are only able to see the computers that they have access to on their on-screen menu.
Configuration • Unit Configuration IP admin password, encryption settings, etc. • Network Configuration IP address, net mask, VNC port, etc. • Serial Configuration Options port usage and Baud rate. • Reset Configuration Completely resets the AdderView CATxIP 5000 unit. To get here 1 From a local keyboard, log on as the ‘admin’ user.
Hardware Indicates the version of the internal circuitry. Firmware Indicates the version of the internal software. Keybd Layout Use the arrow buttons to match the keyboard layout expected by the host system. Admin Passwd Enter the password that will be used to gain administrator access to the AdderView CATxIP 5000. There can only be one admin user and only that user is given access to the configuration menus.
MAC Address Media Access Control address – this is the unique and unchangeable code that was hard coded within your AdderView CATxIP 5000 unit when it was built. It consists of six 2-digit hexadecimal (base 16) numbers separated by colons. A section of the MAC address identifies the manufacturer, while the remainder is effectively the unique electronic serial number of your particular unit. Use DHCP DHCP stands for ‘Dynamic Host Configuration Protocol’.
Serial Configuration Options Port Settings: Power Control, Sync Units Determines whether the RS232 serial OPTIONS port at the rear of the unit will be used for connection to power control switches or to synchronise the operation of two AdderView CATxIP 5000 units. Options Baud Settings: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 This option determines the speed of the RS232 serial OPTIONS port. The other communication settings are fixed as: No parity, 8 bit word, 1 stop bit.
Reset Configuration To reset the AdderView CATxIP 5000 configuration 1 From a local or remote (not accessible from a global keyboard), log on as the ‘admin’ user. 2 Press (hotkeys can change). 3 Press to select ‘More menus’. 4 Select ‘Configuration’. 5 Select ‘Reset Configuration’. 6 Highlight the ‘Reset’ option and press . 7 After a short period, you should see the first of five initial configuration screens. See Initial configuration for details.
Appendix 2 - Configuration pages via viewer This section covers the configuration pages that are available to global admin users, using either the VNC viewer or the browser methods of access. To access the remote configuration pages 1 Make a global connection to the AdderView CATxIP 5000 unit and login as the admin user. 2 Once logged in, click the Configure button in the top right corner of the window.
Confirm Pwd Re-enter your password here to confirm that it is correct. Local When ticked, the selected user can gain access using the local KVM console directly connected to the AdderView CATxIP 5000 unit. Remote When ticked, the selected user can gain access via an IP network link, such as a local intranet or the wider Internet (depending on how the AdderView CATxIP 5000 is connected).
Unit configuration To get here 1 Using VNC viewer or a browser, log on as the ‘admin’ user. 2 Click the ‘Configure’ button in the top right corner. 3 Click the ‘Unit Configuration’ option. Hardware Version Indicates the version of the electronic circuitry within the AdderView CATxIP 5000 unit. Firmware Version Indicates the version of the internal software within the AdderView CATxIP 5000 flash memory. This may be updated using the flash upgrade procedure.
Mouse Rate Defines the rate at which mouse movement data are transmitted to the system. The default option is 20ms, which equates to 50 mouse events per second. This is used to slow down the rate in exceptional circumstances but normally requires no adjustment. Force VNC Protocol 3.3 IMPORTANT: The use of this option is not recommended. Protocol 3.3 is a legacy version that does not offer any encryption. Idle Timeout Determines the period of inactivity on a global connection before the user is logged out.
Timezone specifier Optionally enter a recognised timezone specifier related to the current position of the AdderView CATxIP 5000 unit. When an NTP server is used, the specifier will be used to provide the correct real time.
IP Network Mask Also often called the subnet-mask, this value is used alongside the IP address to help define a smaller collection (or subnet) of devices on a network. In this way a distinction is made between locally connected devices and ones that are reachable elsewhere, such as on the wider Internet. This process helps to reduce overall traffic on the network and hence speed up connections in general.
To get here 1 Using VNC viewer or a browser, log on as the ‘admin’ user. 2 Click the ‘Configure’ button in the top right corner. 3 Click the ‘Network Configuration’ option. Access Use the arrow buttons to select either ‘Allow’ or ‘Deny’ as appropriate. 2 Enter the base network address, the mask and select the appropriate access setting. 3 Click the OK button.
Serial port configuration Baud Rate This option determines the speed of the RS232 serial OPTIONS port. The other communication settings are fixed as: No parity, 8 bit word, 1 stop bit. Options Port Use This option determines whether the RS232 serial OPTIONS port at the rear of the unit will be used for connection to power control switches or to synchronise the operation of two AdderView CATxIP 5000 units.
Sort Allows you to reorder the list of hosts either alphabetically or by entry number. Erase Host Configuration Removes all hosts from the list. To get here 1 Using VNC viewer or a browser, log on as the ‘admin’ user. 2 Click the ‘Configure’ button in the top right corner. 3 Click the ‘Host Configuration’ option. Name Enter the name that will be displayed in the viewer window when you click the Host button. Users Select the users that will be permitted to connect to this host.
Date and time the event occurred Type of event, user name and access method or remote IP address To copy and paste the log You can copy the information listed within the log and paste it into another application. 1 While viewing the log screen, press Ctrl and C, to copy the data into the clipboard. 2 In a text application (i.e. Word, WordPad, Notepad) press Ctrl and V, or right mouse click and ‘Paste’.
LDAP configuration User field Enter the LDAP database field that will be used to match each user name against. The details entered here will depend on the specific LDAP database being used - ‘uid’ or ‘cn’ are commonly used values. Anonymous Bind If left unchecked then bind requests are sent with username (Base DN) and password (more suitable for Active Directory applications). If checked, bind requests are anonymous (more suitable for Linux LDAP implementations).
IMPORTANT: If you make any changes to the options given here and wish to retain them for successive connection sessions, you must save the changes. To do this, change to the ‘Load/Save’ tab and click the ‘Save’ button within the ‘Default’ section. Preferred encoding There are three manually selectable encoding methods which are accessible when the Auto select option is unticked. • ZRLE – This is a highly compressed method that is best suited to slow modem connections.
Customise Allows you to select which data can be transferred between server and viewer. Send pointer events to server When un-ticked, the VNC viewer will not send mouse movement or click data to the AdderView CATxIP 5000 or host system. Pass special keys directly to server When ticked, ‘special’ keys (the Windows key, the Print Screen key, Alt+Tab, Alt+Escape and Ctrl+Escape) are passed directly to the AdderView CATxIP 5000 rather than being interpreted locally.
Misc Full screen mode uses all monitors When ticked, the VNC viewer will show the screen image using all available display monitors on multiple display systems. Enable file transfer This option does not apply to AdderView CATxIP 5000 connections. Enable sound Not supported. Only play sound when window active Not supported. Render cursor locally This option does not currently apply to AdderView CATxIP 5000 connections.
Custom Size Adjusts the server screen image according to the Width and Height settings in the adjacent fields. A drop box to the right of the fields allows you to define the image size by percentage or by pixels, as required. Preserve Aspect Ratio When ticked, maintains a consistent ratio between the horizontal and vertical dimensions of the screen image. Scale to Window Size Adjusts the server screen image to suit the size of the viewer window.
Load / Save Defaults - Reload When clicked, all connection options are returned to the default settings that are currently saved. Defaults - Save When clicked, saves the current connection options as the default set that will be used in all subsequent VNC connections. Configuration File - Save As... Allows you to save the current settings under a new name so that they can be copied from one viewer to another.
Appendix 4 - VNC viewer window options Refresh Screen Requests data from the server for a complete redraw of the screen image, not just the items that change. New connection... Displays the connection dialog so that you can log on to a different AdderView CATxIP 5000 or VNC server location. Options... Displays the full range of connection options - see Appendix 3 for more details. Connection info... Displays various connection and display details. About... Displays information about your VNC viewer.
Encoding and colour level Auto select When ticked, this option will examine the speed of your connection to the AdderView CATxIP 5000 and apply the most suitable encoding method. This option is suggested for the majority of installations. Preferred encoding There are three manually selectable encoding methods which are accessible when the Auto select option is unticked. • ZRLE – This is a highly compressed method that is best suited to slow modem connections.
192.168.142.154 192 is the most global part of the number (akin to the 0044 of the phone number) and 154 is the most local (similar to the 780044 unique local code of the phone number). When two network devices communicate with each other, they always “dial the whole number” regardless of their respective locations in a network. However, they still need to know whether the other device is local to them or not, and this is where the net mask comes into play.
10011010 192 168 142 144 Inside a bit-wise AND function When you “open up” the last octet of the net mask and look at the binary inside, you can see the last four zero bits preventing any 1’s in the address from falling through. Binary equivalent of 154 1111 0 0 0 0 10010000 144 Binary octet after AND operation with net mask Decimal equivalent of 10010000 Thus, when 154 is bit-wise ANDed with 240, the result is 144. Likewise, any local address from 192.168.142.144 through to 192.168.142.
Address ranges Although you can define ranges of addresses, due to the way that the mask operates, there are certain restrictions on the particular ranges that can be set. For any given address you can encompass neighbouring addresses in blocks of either 2, 4, 8, 16, 32, 64, 128, etc. and these must fall on particular boundaries. For instance, if you wanted to define the local address range: 192.168.142.67 to 192.168.142.93 The closest single block to cover the range would be the 32 addresses from: 192.168.
User with VNC viewer accesses IP address: 129.7.1.10 (this automatically uses port 5900). Router/firewall address: 129.7.1.10 Router is programmed to send port 5900 VNC traffic to local address 192.168.0.3 and port 80 web traffic to local address 192.168.0.42 LOC REM VNC 100 LNK PWR www.adder.com AdderView CATxIP 5000 has the local IP address: 192.168.0.
Appendix 7 – Cascading multiple units AdderView CATx 1000 CAM CAM CAM CAM CAM CAM CAM CAM Cascade level 2 AdderView CATxIP 5000 AdderView CATx 1000 CAM CAM CAM CAM Cascade level 1 The cascade tree The diagram shows how an AdderView CATxIP 5000 unit and multiple AdderView CATx 1000 units can be cascaded to two levels. Computer systems can be connected at any level.
7 6 5 CO MP 3 UT ER CO NN 2 EC T ION 3 Connect the other end of the cascade link cable to the remote user port (RJ45 socket) on the front panel of the �������������������������� AdderView CATx 1000������� unit. 4 Repeat steps 2 and 3 for the cascade links between the AdderView CATxIP 5000 and each ����� AdderView CATx 1000 unit.
Addressing computers in a cascade CAM CAM 08 Using cascaded computers In use, cascaded computers can be accessed using exactly the same methods as for those connected directly to the AdderView CATxIP 5000. However, by far the easiest way is to use the on screen menu. This is because it displays the computer names and does not require any knowledge of port addresses. See either Selecting a computer (for local user access) or Host selection (for global user access) for more details.
Appendix 8 – Cable and connector specifications Use this cable when two AdderView CATxIP 5000 devices are being synchronised. Power switch to power switch daisy chain cable 4pin RJ9 MASTER end 9pin D-type female SLAVE1 end 9pin D-type female 4pin RJ9 Use this cable when three AdderView CATxIP 5000 devices are being synchronised.
Appendix 9 – Hotkey sequence codes Math operand keys (see ‘Using abbreviations’) Add (Plus) | Subtract (Minus) | Multiply Central control keys (see ‘Using abbreviations’) Insert | Delete | Home | End | PageUp | PageDown Up | Down | Left | Right | Print | Pause Keypad keys (see ‘Using abbreviations’) KP_Insert | KP_Delete | KP_Home | KP_End | KP_PageUp KP_PageDown | KP_Up | KP_Down | KP_Left | KP_Right | KP_Enter KP_Add | KP_Subtract | KP_Divide | KP_Multiply KP_0 to KP_9 Function keys F1 | F2 | F3 | F
vesa 720 x 400 @ 85Hz sun 1152 x 900 @ 66Hz vesa 640 x 480 @ 60Hz sun 1152 x 900 @ 76Hz vesa 640 x 480 @ 72Hz sun 1280 x 1024 @ 67Hz vesa 640 x 480 @ 75Hz apple 640 x 480 @ 67Hz vesa 640 x 480 @ 85Hz apple 832 x 624 @ 75Hz vesa 800 x 600 @ 56Hz apple 1152 x 870 @ 75Hz vesa 800 x 600 @ 72Hz 1920 x 1200 @ 60Hz** vesa 800 x 600 @ 75Hz vesa 800 x 600 @ 85Hz vesa 1024 x 768 @ 60Hz vesa 1024 x 768 @ 70Hz vesa 800 x 600 @ 60Hz The following video modes are supported and ca
Safety considerations when using power switches with AdderView CATxIP 5000 • Follow the manufacturer’s instructions when setting up and using power switching products. • Always ensure that the total ampere rating of the devices plugged into the power switching product does not exceed the power switching product’s ampere rating. Also, make sure that the total ampere rating of all the devices plugged into the wall outlet does not exceed the wall outlet’s ampere rating.
2. Permitted and Prohibited Uses 2.1 During the term of this Agreement and as long as you comply with the terms of this agreement, you may use the Software only with the Product for your personal use or for the internal use of your business. You may make as many copies of the Software as you require for your own internal business purposes only and for archival purposes.
Canadian Department of Communications RFI statement This equipment does not exceed the class A limits for radio noise emissions from digital apparatus set out in the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le règlement sur le brouillage radioélectriques publié par le ministère des Communications du Canada.
Adder Asia Pacific 6 New Industrial Road, Hoe Huat Industrial Building #07-01, Singapore 536199 Tel: +65 6288 5767 Fax: +65 6284 1150 Adder Corporation, 350R Merrimac Street, Newburyport, MA 01950, United States of America Tel: +1-888-932-3337 Fax: +1-888-275-1117 Adder Technology Limited, Technology House, Trafalgar Way, Bar Hill, Cambridge, CB23 8SQ, United Kingdom Tel: +44 (0)1954 780044 Fax: +44 (0)1954 780081 © 2010 Adder Technology L
D Daisy chain cable 85 Date local setting 56 DHCP discovering allocations 27 during initial setup 18 remote setting 65 DNS addressing 27 G Gateway local setting 57 remote setting 65 Global preferences 53,55 Global user access 37 connection 12 H Hextile 71,77 Host computer changing between 40,41 configuration 68 connecting 10 connection 12 power switching setup 29 selection 41 I Identities VNC Viewer 75 Indicators 6,31 Initial configuration 17 IP access control 65,66 calculating mask 80 clearing 22 IP addr
N Net mask 57 explanation 78 Network configuration 57,65 Networking issues 25 Network port connection 11 S Safety information 88 Saving configuration settings 21 Scaling VNC Viewer 74 Screen best resolution 40 calibration 42 navigation 40 refresh 43 Screensaver local setting 56 Security enabling 20 ensuring 28 general steps 20 T Threshold adjustment 45 Time local setting 56 Time & date configuration 64 Troubleshooting 49 V Video modes 87 Video settings 43 Viewer window 40 VNC port initial setup 18 local