Datasheet
AddOn Computer Phone: 877.292.1701
Page 7 of 11
J9151A-AO
HP, 10GBASE-LR SFP+ MMF
1310NM 10KM REACH LC
Receiver power (damage, Max)
1.5
dBm
Note:
1. Average optical power shall be measured using the methods spevified in
TIA/EIA-455-95.
2. Receiver sensitivity is informative. Stressed receiver sensitivity shall be
measured with conformance test signal for BER =1x 10
-12
3. Vertical eye closure penalty and stressed eye jitter are the test conditions for
measuring stressed receiver sensitivity. They are not the required characteristic
of the receiver.
4. Power budget is defined as the different between the Rx sensitivity and the Tx.
Output power of the interface.
5. Path penalty is intended as the power penalty of the interface between back-to-
back and the maximum applied dispersion.
8. DIGITAL DIAGNOSTIC FUNCTIONS
The following digital diagnostic characteristics are defined over the
Recommended Operating Environment unless otherwise specified. It is compliant
to SFF8472 Rev10.2 with internal calibration mode. For external clibration please
contact our sales staff.
Table 5: Digital diagnostic specification table
Parameters
Symbol
Min.
Max.
Unit
Notes
Temperature monitor
absolute error
DMI_Temp
-3
3
degC
Over operating temp
Laser power monitor
absolute error
DMI_TX
-3
3
dB
RX power monitor
absolute error
DMI_RX
-3
3
dB
-1dBm to -15dBm
range
Supply voltage
monitor absolute error
DMI_VCC
-0.08
0.08
V
Full operating range
Bias current monitor
DMI_Ibias
-10%
10%
mA