850NM 300M REACH LC 
Digital Optical Monitoring 
Transceivers offer the ability to monitor important module parameter during operation. 
The five parameters listed below are continuously monitored for getting information 
about the current module status. All data is calibrated internally; there is no need for 
external post processing. 
Temperature 
Internally measured temperature data is represented as two’s complement of a signed 
16-bit value in increments of 1/256 °C over a range of -40 to +100°C. Accuracy is better 
than +/-3%. 
Supply Voltage (VCC) 
Internally measured supply voltage. Represented as a 16-bit unsigned integer with the 
voltage defined as the full 16 bit value (0 – 65535) with LSB equal to 100 µVolt, which 
yields to a total range of 0 to +6.55 Volts. Accuracy is better than +/-3%. 
Laser Bias Current 
VCSEL bias current. Represented as a 16 bit unsigned integer with the current defined 
as the full 16-bit value (0 – 65535) with LSB equal to 2 µA, valid range is 0 to 20 mA. 
Accuracy is better than +/-10%. 
Optical Transmitter Power 
TX output power measurement is based on internal monitor diode feedback. 
Represented as a 16-bit unsigned integer with the power defined as the full 16 bit value 
(0–65535) with LSB equal to 0.1µW. Accuracy is better than +/-3dB over a range of 
Pavmin to Pavmax. 
Receiver Optical Power 
RX input power measurement is based on photodiode diode current. Represented as a 
16-bit unsigned integer with the power defined as the full 16 bit value (0 – 65535) with 
LSB equal to 0.1 µW. Accuracy is better than +/-3dB over a range of -12dBm to -1dBm. 
Note: The specified characteristics are met within the recommended range of operating 
conditions regarding temperature and voltage. 
Regulatory Compliance  
Module Safety  
Addon Computer SFP+ modules are designed to meet international requirements and 
standards in terms of product safety. Tests were performed according 
to IEC 60950-1:2001 (CB scheme).The module is RoHS compliant according to the 
European Parliament requirements on the restriction of the use of hazardous substances 
in electrical and electronic equipment (RoHS). The modules optical output power 
meet Class 1 requirements for laser safety. 