BLADE, 10GBASE-SR SFP+ MMF
850NM 300M REACH LC
(0–65535) with LSB equal to 0.1µW. Accuracy is better than +/-3dB over a range of
Pavmin to Pavmax.
Receiver Optical Power
RX input power measurement is based on photodiode diode current. Represented as a
16-bit unsigned integer with the power defined as the full 16 bit value (0 – 65535) with
LSB equal to 0.1 µW. Accuracy is better than +/-3dB over a range of -12dBm to -1dBm.
Note: The specified characteristics are met within the recommended range of operating
conditions regarding temperature and voltage.
Regulatory Compliance
Module Safety
Proline SFP+ modules are designed to meet international requirements and standards in
terms of product safety. Tests were performed according
to IEC 60950-1:2001 (CB scheme).The module is RoHS compliant according to the
European Parliament requirements on the restriction of the use of hazardous substances
in electrical and electronic equipment (RoHS). The modules optical output power
meet Class 1 requirements for laser safety.
Requirements
Standard
Status
Module
Safety
IEC 60950-1:2001 EN 60950-
1:2001
TUV Report / Certificate available CB
Report / Certificate available
RoHS
RoHS Directive 2002/95/EC
RoHS 6/6 compliant Certificate of
Compliance
Amendment 4054 (2005/747/EC)
compliance available
Laser Eye
CDRH 21 CFR 1040.10 and
Laser Class 1 according to FDA
Safety
1040.11 IEC 60825-1 Rev2 2007
Laser Class 1 according to IEC Rev2
ESD & Electromagnetic compatibility
Add-On Computer Peripherals SFP+ modules are designed to withstand high ESD
voltages. Its excellent performances in terms of EMI allow system designers to integrate
the module in high density applications.
Requirements
Standard
Status
Electro Static
Discharge to the
Electrical Pins (ESD)
EIA/JESD22-A114-B MIL-
STD 883C Method 3015.7
Exceeds requirements Class 1B
(>1000V)
Exceeds requirements
Immunity to ESD
IEN 61000-4-2
Discharges ranging from 2kV to
(housing, receptacle)
IEC61000-4-2
25kV without damages to the
transceiver
Electromagnetic
FCC Part 15, Class B EN
Exceeds requirements Class B