Datasheet

AddOn Computer Phone: 877.292.1701
Page 3 of 10
BN-CKM-SP-SR-AO
BLADE, 10GBASE-SR SFP+ MMF
850NM 300M REACH LC
Static Discharge Voltage Module on
SFP+
EN61000-4-2
Criterion B: Air
Discharge Direct
Contact discharge
15
8
kV
Any stress beyond the maximum ratings may result in permanent damage to the device.
Specifications are guaranteed only under recommended operating conditions.
Recommended Operating Conditions
Parameter
Conditions
Symbol
Min.
Typical
Max.
Unit
Operating Case Temperature
altitude of < 3km
JCase
0
+70
°C
Power Supply Voltage@3.3V
Vcc3
3.135
3.30
3.465
V
DC Common Mode Voltage
Vcm
0
3.6
V
Low Speed Characteristics
Parameter
Conditions
Symb
ol
Min
Max
Unit
s
Supply Current Transmitter
@ VCCTX
IVCCT
X
120
mA
Supply Current Receiver
@ VCCRX
IVCC
RX
125
mA
Power Consumption
1
W
VOL
0
0.4
TX_Fault, RX_LOS
Host Vcc Range
2V – 3.47V
VOH
Host_ Vcc –
0.5
Host_ Vcc
+0.3
VIL
-0.3
0.8
TX_Dis, RS0, RS1
Low Voltage TTL
VIH
2.0
VccT +0.3
SCL, SDA
Host Vcc Range
VIL
-0.3
VccT*0.3
V
VIH
VccT*0.7
VccT +0.5
VOL
0.0
0.4
3.14V – 3.47V
VOH
Host_ Vcc –
0.5
Host_ Vcc +0.3
SFI Module Transmitter Input Characteristics