Datasheet
AddOn Computer Phone: 877.292.1701 
Page 7 of 10 
10G-SFPP-LR-AO 
BROCADE, 10GBASE-SR SFP+ MMF 
850NM 300M REACH LC 
Note: 
1.  Average optical power shall be measured using the methods spevified in 
TIA/EIA-455-95. 
2.  Receiver sensitivity is informative. Stressed receiver sensitivity shall be 
measured with conformance test signal for BER =1x 10
-12
3.  Vertical eye closure penalty and stressed eye jitter are the test conditions for 
measuring stressed receiver sensitivity. They are not the required characteristic 
of the receiver.  
4.  Power budget is defined as the different between the Rx sensitivity and the Tx. 
Output power of the interface. 
5.  Path penalty is intended as the power penalty of the interface between back-to-
back and the maximum applied dispersion. 
8. DIGITAL DIAGNOSTIC FUNCTIONS 
The following digital diagnostic characteristics are defined over the 
Recommended Operating Environment unless otherwise specified. It is compliant 
to SFF8472 Rev10.2 with internal calibration mode. For external clibration please 
contact our sales staff. 
Table 5: Digital diagnostic specification table 
Parameters 
Symbol 
Min.  
Max.  
Unit  
Notes 
Temperature monitor 
absolute error 
DMI_Temp 
-3 
3 
degC 
Over operating temp 
Laser power monitor 
absolute error 
DMI_TX 
-3 
3 
dB 
RX power monitor 
absolute error 
DMI_RX 
-3 
3 
dB 
-1dBm to -15dBm 
range 
Supply voltage 
monitor absolute error 
DMI_VCC 
-0.08 
0.08 
V 
Full operating range 
Bias current monitor 
DMI_Ibias 
-10% 
10% 
mA 