User manual

A511 User Manual, Rev. 1.1 - 9 - 08/2007
Solar Panel Measurement
This screen shows how much power (in V and mA) a solar panel generates. Voltage is
measured using a load of 22 Ohm.
Caution:
The circuitry used for measuring solar power is not made to dissipate the power
generated by long term testing. Please use this mode only for an instantaneous test
of your solar panel! Leaving the solar panel test running continuously can build up
heat and could damage the A511.
Figure 8: Solar Panel Measurement, no panel attached
Battery Status and Sensor Supply Current
Shows the power status of the A511’s internal battery. It also displays the power
consumption of ALL
the sensors connected to the device.
Figure 9: Battery status and current used by sensors
4.2. Configuration settings of the Analog Measurement Mode
The Default Settings of the A511:
„Perm.Supply“ = Permanent Operation OFF - auto-OFF after 60 seconds ON
„Meas.“ Measuring Method = Permanently Update sensor readings
„AVG“ Averaging = OFF, do not average readings