User's Manual
Table Of Contents
- Objective
- Module introduction
- Basic Operation
- General
- "Hayes" Mode
- "Point-to-Point" Mode
- "Network" Mode
- Demo Kit Utilization
- Installation and Connection
- WinB900 Software Utilization in Point-to-Point Mode
- The different fields and buttons are described below:
- "Sent Characters" Field
- "Received Characters" Field
- "Test Frames" Selection
- "Characters Count" Field
- Button: "Send"
- Button: "Continuous"
- Button: "Initialization"
- Button: "Stop"
- Button: "Quit"
- "Character Count Sent/Received" Fields
- "Elapsed time" Field
- "Sent/Received/Corrupted Count" Fields
- "Stop on Error" Selection
- Use of the WinB900 Software in Network Mode
- Use of the "Terminal" or "HyperTerminal" Software
- Advanced Operation
- Appendix 1: Schematic Block Diagram
- Appendix 2: Mechanical Drawings
- Appendix 3: Antenna Connection
- A
- Appendix 5: Timing Diagrams
- Appendix 6: Description of the registers
- Appendix 7: Revisions History
45
Access
Type
Register
Name Description
Operation
OperationOperation
Operation
R/W S220 Server or Client Mode Indicates the operation of the Modem. When the Modem is
configured as Master (or Server), the S252 Register switches
automatically to 0xFF, while it switches to 0 when configured
as Slave (or Client).
'0' : Server (Network),
'1' : Client (Network),
'2' : Master,
'3': Slave (Default).
'3': Slave (Default).'3': Slave (Default).
'3': Slave (Default).
R/W S221 Recovery Count Maximum recovery count in case of problems (Non-Ack
response to a message).
If this Register is at 0, the frames are not checked and
considered as still good (used for the tests).
Default: 2.
Default: 2.Default: 2.
Default: 2.
P
PP
Personal Network Control
ersonal Network Controlersonal Network Control
ersonal Network Control
R/W S250
Number of Personal Network
(or Network)
This register gives the Personal Network (Network) number on
2 Bytes. Only the two members of a same Personal Network
can communicate with each other. Between 0 and 65535, it is
at 0 when the modem is not reset.
NOTE
: To reset the register to 0 also resets the S252 Register
to 0.
Default: 0.
Default: 0.Default: 0.
Default: 0.
R S252 Modem Number Gives the Modem a unique number for a given Personal
Network. Number on one Byte is 0 when the Modem is not
reset, 1 if it is a Slave, between 1 and 6 if it is a Client and 255
if it is the Master.
Default: 0.
Default: 0.Default: 0.
Default: 0.
R S253 Clients Count Gives the Client count of a Master Modem or a Server.
Default: 0.
Default: 0.Default: 0.
Default: 0.
R/W S254 Client Addition Gives the number of a Client to be added in the already set
up network. This number should be between 1 and S253. Only
used on a Network Server.
Default: 0.
Default: 0.Default: 0.
Default: 0.