User's Manual

CHAPTER 3
Advanced Functions
38
RSET
DESCRIPTION Issues remote SET commands, which set parameters in the RTUs.
Not all the RTUs support these commands, most notably the
A730MD devices don’t support it.
PARAMETERS The ID of the remote, the set-command, and its parameters.
RETURNS OK or an error message.
REMARKS Currently only the A720 (series 2), A723 (series 3) addIT, and the
A733 addWAVE devices support this command. The following
remote set commands are supported: ID, SLOT, PMP, FREQ, FDEV,
and SST. Not all devices support all commands.
EXAMPLE rset 11123 slot 600 10
OK
Error Messages
The emu3ap software might return any of several error messages.
Some are self-recoverable after a retry and others are simply warn-
ings. These messages are returned instead of the OK prompt.
1 — Nonexistent command
2 — CLI buffer overflow
3 — Internal error
5 — Invalid or missing parameter
10 — Device not found
11 — Device already exists
13 — No more space for device descriptors
14 — No more records for the requested device
15 — Remote device currently unavailable (radio connection
temporarily interrupted)
18 — Reserved device numbers (that is, 0)
20 — Incorrect time supplied, conversion not possible
30 — Error receiving a frame (cyclic redundancy check and
others)
31 — An unexpected frame type was received
32 — False length (type does not fit its length)
35 — Radio timeout when receiving (no answer after a request
36 — RF channel in use