User's Manual
CHAPTER 3
Operations at the Application Level
37
From 2646: incoming RF 188, outgoing RF 141
From 9474: incoming RF 255, outgoing RF 255
From 2419: incoming RF 255, outgoing RF 254
From 2464: incoming RF 255, outgoing RF 255
From 10843: incoming RF 255, outgoing RF 255
OK
RB
DESCRIPTION Forces the speciļ¬ed remote device to issue a broadcast request
frame that forces all listening devices to answer. By subsequently
using the RBLIST command, a list of all the stations heard from can
be retrieved.
PARAMETERS The ID of the remote.
RETURNS OK or error.
REMARKS Currently only the A723 addIT and the A733 addWAVE devices
support this command. At least 12 seconds must elapse between
the time you issue the RB and RBLIST commands.
EXAMPLE rb 9473
Error level: 0
OK
RBLIST
DESCRIPTION Returns a list of all the stations heard from after a broadcast
request.
PARAMETERS The ID of the remote.
RETURNS A list of the stations heard from.
REMARKS Currently only the A723 addIT and the A733 addWAVE devices
support this command. At least 12 seconds must elapse between
the time you issue the RB and RBLIST commands.
EXAMPLE rblist 9473
Dev 9473: incoming RF 255, outgoing RF 255
Last Broadcast: Mon Jun 19 12:50:31 2000
201: 255
4446: 255
2622: 255
6127: 255
10820: 255
11127: 255
2646: 255
2008: 255
OK