30
The A431 Radio Module
Commands valid for all bands
ID 1
PMP 65 72
SLOT 900 15
RSSI 58
Commands required for band 1
TF 430000000
BL 430000000 440000000
FREQ 430000000 12500
Commands required for band 2
TF 440000000
BL 440000000 450000000
FREQ 440000000 12500
Commands required for band 3
TF 450000000
BL 450000000 460000000
FREQ 450000000 12500
Commands required for band 4
TF 460000000
BL 460000000 470000000
FREQ 460000000 12500
Note: The TF command sets the start tuning frequency, the BL command sets the
band limits, and the FREQ command sets the actual operating frequency;
before shipping and depending on the target country, the last two parame-
ters may be changed. The BL command must always be issued before the
FREQ command.