Technical Manual

Table Of Contents
15
External Power Supply
when the battery voltage drops below 5.6 Volts, and under 5.9 Volts the RF opera-
tion may stop.
Figure 4.
Connection of an external power supply.
2.2. Specifications
The A733 fulfills the specifications of the EN 300 220-1, Class 12, ETS 300 086 and
ETS 300 113, as well as the FCC Part 90.214 (Subpart J) of the CFR 47.
Note: The parameters below were measured with the A733 + A431 combination.
Parameter Min Typ Max Unit
Common
Supply 5.6 6.2 10.0 V
Operating Temperature -30 +70 °C
Relative Humidity 99 %
Class Protection IP65
Data Rate (Using the On-board Software Modem) 1000 1500
a
2000 bps
Operating Frequency (-44 version)
b
430 450 MHz
Operating Frequency (-46 version)
b
450 470 MHz
Frequency Stability (-20 to +50°C) ±1.5 kHz
Frequency Stability (-30 to +60°C) ±2.5 kHz
Receiver
Sensitivity (12 db S/S+N) -118 dBm
Image Frequency Attenuation (1st IF = 45 MHz) -70 dB
POWER
I/O C
I/O D
+
-
Black
Red
5 to 10 Volt
RS232
+
+
Power Cable Serial Adapter Cable
I/O A
I/O B
ANT