User`s manual

76
BURNER PURGE FAULT - The gas valve signal is present during the prepurge time.
MODEL ERROR, ENTER CORRECT MODEL - The wrong model was selected for the dryer.
EE PROM FAULT ### - Error in memory location. The ### indicates the location of the fault.
B. INPUT/OUTPUT (I/O) BOARD LIGHT EMITTING DIODE (L.E.D.)
INDICATORS
1. INPUTS
1. ESTOP – (RED L.E.D.) This L.E.D. will indicate the status of the E-STOP. If the E-STOP has been
pressed, then the L.E.D. is ON.
2. GAS_V (RED L.E.D.) This L.E.D. will indicate the status of the gas valve. If the gas valve is open
(ON), then the L.E.D. is ON.
3. BRHL (RED L.E.D.) This L.E.D. will indicate the status of the burner high limit disk. If the disk is
closed (temperature below 330º F [166º C]), then the L.E.D. is ON.
4. SAIL (RED L.E.D.) This L.E.D. will indicate the status of the sail switch. If the switch is closed, then
the L.E.D. is ON.
5. EXHL (RED L.E.D.) This L.E.D. will indicate the status of the exhaust high limit disk. If the disk is
closed (temperature below 225º F [107º C]), then the L.E.D. is ON.
6. MAIN (RED L.E.D.) This L.E.D. will indicate the status of the main door. If the door is closed, then
the L.E.D. is ON.
7. LINT (RED L.E.D.) This L.E.D. will indicate the status of the lint drawer. If the drawer is closed,
then the L.E.D. is ON.
8. FUSE (RED L.E.D.) This L.E.D. will indicate the status of the control voltage. If the POWER ON
button is pressed (green button light is on), then the L.E.D. is ON.