User`s manual
74
SECTION IX
PHASE 7 AUTO CYCLE (PATENT NO. 4,827,627)
CYCLE ADJUSTMENT VALUES
IMPORTANT: If your particular model/dryer dryness levels are not shown in the above charts,
contact the ADC Service Department for the appropriate factors for your particular
dryer. When doing so, please have the dryer model and serial numbers available.
IMPORTANT: The adjustment values have been preprogrammed by the factory, but can be changed
in the field. If the Phase 7 OPL microprocessor controller (computer) should fail and
is being replaced. THE REPLACEMENT PHASE 7 OPL
MICROPROCESSOR CONTROLLER (COMPUTER) MUST BE
REPROGRAMMED FOR THE SPECIFIC MODEL SHOWN IN THE
ADJUSTMENT VALUE PARAMETERS CHARTS ABOVE. THE
ADJUSTMENT VALUE LABEL IS LOCATED ON THE TOP CONTROL
PANEL, BEHIND THE PHASE 7 KEYBOARD (TOUCH PAD) DISPLAY
DOOR.
NOTE: When fine-tuning the Auto Cycle for certain loads, if the material comes out wet, decrease the
adjustment value, if the material comes out too dry, increase the adjustment value.
ELECTRIC
MODEL
Adjustment
Value
ADE-30 68
ADE-50 70
ADE-60 65
ADE-75 70
ADE-115 60
ADE-120ES 78
MLE-55 65
MLE-75 70
MLE-120ES 78
EURO-14 68
EURO-24 70
EURO-35 70
GAS
MODEL
Adjustment
Value
ADG-30 68
ADG-50 70
ADG-60 65
ADG-75 70
ADG-78 70
ADG-81 70
ADG-115D 68
ADG-120ES 73
ADG-170SE 68
MLG-55 65
MLG-75 70
MLG-78 70
MLG-82 70
MLG-96 70
MLG-122 70
MLG-130 73
MLG-170/175 68
MLG-190 70
EURO-14 68
EURO-24 70
EURO-35 70
STEAM
MODEL
Adjustment
Value
ADS-30 68
ADS-60 65
ADS-75 70
ADS-115 68
ADS-120ES 65
ADS-170ES 70
MLS-55 65
MLS-75 70
EURO-14 68
EURO-24 70
EURO-35 70